Simulation-based Evaluation and Optimization of a New CdZnTe Gamma-camera Architecture (HiSens)

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2010 Apr 20
PMID 20400808
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

A new gamma-camera architecture named HiSens is presented and evaluated. It consists of a parallel hole collimator, a pixelated CdZnTe (CZT) detector associated with specific electronics for 3D localization and dedicated reconstruction algorithms. To gain in efficiency, a high aperture collimator is used. The spatial resolution is preserved thanks to accurate 3D localization of the interactions inside the detector based on a fine sampling of the CZT detector and on the depth of interaction information. The performance of this architecture is characterized using Monte Carlo simulations in both planar and tomographic modes. Detective quantum efficiency (DQE) computations are then used to optimize the collimator aperture. In planar mode, the simulations show that the fine CZT detector pixelization increases the system sensitivity by 2 compared to a standard Anger camera without loss in spatial resolution. These results are then validated against experimental data. In SPECT, Monte Carlo simulations confirm the merits of the HiSens architecture observed in planar imaging.

Citing Articles

Evaluation of a variable-aperture full-ring SPECT system using large-area pixelated CZT modules: A simulation study for brain SPECT applications.

Huh Y, Yang J, Dim O, Cui Y, Tao W, Huang Q Med Phys. 2021; 48(5):2301-2314.

PMID: 33704793 PMC: 8141019. DOI: 10.1002/mp.14836.


Technical Note: Nuclear imaging with an x-ray flat panel detector: A proof-of-concept study.

Dietze M, Koppert W, van Rooij R, W A M de Jong H Med Phys. 2020; 47(8):3363-3368.

PMID: 32314368 PMC: 7496965. DOI: 10.1002/mp.14191.


Molecular Breast Imaging using Synthetic Projections from High-Purity Germanium Detectors: A Simulation Study.

Campbell D, Peterson T IEEE Trans Radiat Plasma Med Sci. 2017; 1(5):405-415.

PMID: 28989990 PMC: 5629019. DOI: 10.1109/TRPMS.2017.2725310.


An energy-optimized collimator design for a CZT-based SPECT camera.

Weng F, Bagchi S, Zan Y, Huang Q, Seo Y Nucl Instrum Methods Phys Res A. 2015; 806:330-339.

PMID: 26640308 PMC: 4665111. DOI: 10.1016/j.nima.2015.09.115.


Molecular breast imaging: an emerging modality for breast cancer screening.

OConnor M Breast Cancer Manag. 2015; 4(1):33-40.

PMID: 25621015 PMC: 4303579. DOI: 10.2217/BMT.14.49.