Radiation Dose and Cancer Risk from Pediatric CT Examinations on 64-slice CT: a Phantom Study

Overview
Journal Eur J Radiol
Specialty Radiology
Date 2010 Apr 6
PMID 20363573
Citations 23
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To measure the radiation dose from CT scans in an anthropomorphic phantom using a 64-slice MDCT, and to estimate the associated cancer risk.

Materials And Methods: Organ doses were measured with a 5-year-old phantom and thermoluminescent dosimeters. Four protocols; head CT, thorax CT, abdomen CT and pelvis CT were studied. Cancer risks, in the form of lifetime attributable risk (LAR) of cancer incidence, were estimated by linear extrapolation using the organ radiation doses and the LAR data.

Results: The effective doses for head, thorax, abdomen and pelvis CT, were 0.7mSv, 3.5mSv, 3.0mSv, 1.3mSv respectively. The organs with the highest dose were; for head CT, salivary gland (22.33mGy); for thorax CT, breast (7.89mGy); for abdomen CT, colon (6.62mGy); for pelvis CT, bladder (4.28mGy). The corresponding LARs for boys and girls were 0.015-0.053% and 0.034-0.155% respectively. The organs with highest LARs were; for head CT, thyroid gland (0.003% for boys, 0.015% for girls); for thorax CT, lung for boys (0.014%) and breast for girls (0.069%); for abdomen CT, colon for boys (0.017%) and lung for girls (0.016%); for pelvis CT, bladder for both boys and girls (0.008%).

Conclusion: The effective doses from these common pediatric CT examinations ranged from 0.7mSv to 3.5mSv and the associated lifetime cancer risks were found to be up to 0.16%, with some organs of higher radiosensitivity including breast, thyroid gland, colon and lungs.

Citing Articles

A Low-Cost, Portable, Multi-Cancer Screening Device Based on a Ratio Fluorometry and Signal Correlation Technique.

Alghamdi A, Aldhaheri R Biosensors (Basel). 2024; 14(10).

PMID: 39451695 PMC: 11506725. DOI: 10.3390/bios14100482.


Optimal image quality and radiation doses with optimal tube voltages/currents for pediatric anthropomorphic phantom brains.

Chen L, Kao H, Wu P, Sheu M, Huang L PLoS One. 2024; 19(7):e0306857.

PMID: 39037987 PMC: 11262643. DOI: 10.1371/journal.pone.0306857.


Optimizing CT Abdomen-Pelvis Scan Radiation Dose: Examining the Role of Body Metrics (Waist Circumference, Hip Circumference, Abdominal Fat, and Body Mass Index) in Dose Efficiency.

Almohammed H, Elshami W, Hamd Z, Abuzaid M Tomography. 2024; 10(5):643-653.

PMID: 38787009 PMC: 11126040. DOI: 10.3390/tomography10050049.


Factors contributing to uncertainty in paediatric abdominal ultrasound reports in the paediatric emergency department.

Hwang S, Chung H, Park J, Lee E, Lee H, Kim J BMC Emerg Med. 2023; 23(1):120.

PMID: 37817121 PMC: 10566031. DOI: 10.1186/s12873-023-00892-w.


The usefulness of selected sequences of magnetic resonance imaging in a diagnostic model for Crohn's disease.

Tomicka-Szymanska B, Kaszubowski M, Winklewski P, Pienkowska J, Wypych J, Janiak M Prz Gastroenterol. 2022; 17(4):316-320.

PMID: 36514457 PMC: 9743332. DOI: 10.5114/pg.2022.121824.