» Articles » PMID: 20354054

Passive Airborne Dust Sampling with the Electrostatic Dustfall Collector: Optimization of Storage and Extraction Procedures for Endotoxin and Glucan Measurement

Overview
Journal Ann Occup Hyg
Date 2010 Apr 1
PMID 20354054
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

We recently introduced a passive dust sampling method for airborne endotoxin and glucan exposure assessment-the electrostatic dustfall collector (EDC). In this study, we assessed the effects of different storage and extraction procedures on measured endotoxin and glucan levels, using 12 parallel EDC samples from 10 low exposed indoor environments. Additionally, we compared 2- and 4-week sampling with the prospect of reaching higher dust yields. Endotoxin concentrations were highest after extraction with pyrogen-free water (pf water) + Tween. Phosphate-buffered saline (PBS)-Tween yielded significantly (44%) lower levels, and practically no endotoxin was detected after extraction in pf water without Tween. Glucan levels were highest after extraction in PBS-Tween at 120 degrees C, whereas extracts made in NaOH at room temperature or 120 degrees C were completely negative. Direct extraction from the EDC cloth or sequential extraction after a preceding endotoxin extraction yielded comparable glucan levels. Sample storage at different temperatures before extraction did not affect endotoxin and glucan concentrations. Doubling the sampling duration yielded similar endotoxin and only 50% higher glucan levels. In conclusion, of the tested variables, the extraction medium was the predominant factor affecting endotoxin and glucan yields.

Citing Articles

Passive Bioaerosol Samplers: A Complementary Tool for Bioaerosol Research. A Review.

Manibusan S, Mainelis G J Aerosol Sci. 2022; 163.

PMID: 36386279 PMC: 9648171. DOI: 10.1016/j.jaerosci.2022.105992.


Establishing farm dust as a useful viral metagenomic surveillance matrix.

Kwok K, de Rooij M, Messink A, Wouters I, Smit L, Cotten M Sci Rep. 2022; 12(1):16308.

PMID: 36175536 PMC: 9521564. DOI: 10.1038/s41598-022-20701-x.


Effect of air filtration on house dust mite, cat and dog allergens and particulate matter in homes.

Maya-Manzano J, Pusch G, Ebner von Eschenbach C, Bartusel E, Belzner T, Karg E Clin Transl Allergy. 2022; 12(4):e12137.

PMID: 35474731 PMC: 9022093. DOI: 10.1002/clt2.12137.


Effectiveness of portable HEPA air cleaners on reducing indoor endotoxin, PM and coarse particulate matter in an agricultural cohort of children with asthma: A randomized intervention trial.

Riederer A, Krenz J, Tchong-French M, Torres E, Perez A, Younglove L Indoor Air. 2021; 31(6):1926-1939.

PMID: 34288127 PMC: 8577577. DOI: 10.1111/ina.12858.


Household dampness and microbial exposure related to allergy and respiratory health in Danish adults.

Juel Holst G, Porneki A, Lindgreen J, Thuesen B, Bonlokke J, Hyvarinen A Eur Clin Respir J. 2020; 7(1):1706235.

PMID: 32128077 PMC: 7034447. DOI: 10.1080/20018525.2019.1706235.