Abstract

Recent reports have demonstrated the multi-analyte detection capability of paper networks with multiple outlets per inlet. In this report, we focus on the capabilities of 2D paper networks with multiple inlets per outlet and demonstrate the controlled transport of reagents within paper devices. Specifically, we demonstrate methods of controlling fluid transport using the geometry of the network and dissolvable barriers. Finally, we discuss the implications for higher sensitivity detection using this type of 2D paper network.

Citing Articles

Enhancing Sensitivity in SARS-CoV-2 Rapid Antigen Testing through Integration of a Water-Soluble Polymer Wall.

Wang X, Wang Y, Jie H, Liu S, Shen C, Liu Q Biosensors (Basel). 2024; 14(6).

PMID: 38920609 PMC: 11201958. DOI: 10.3390/bios14060305.


Microfluidic paper analytic device (μPAD) technology for food safety applications.

Soman S, Samad S, Venugopalan P, Kumawat N, Kumar S Biomicrofluidics. 2024; 18(3):031501.

PMID: 38706979 PMC: 11068414. DOI: 10.1063/5.0192295.


Flow control by circular cavities in lateral flow porous membranes.

Jamil S, Abbasi M, Jafry A, Shahzad T, Sarwar S, Qureshi M Sci Prog. 2024; 107(1):368504241235508.

PMID: 38426804 PMC: 10908241. DOI: 10.1177/00368504241235508.


Improved sensitivity and automation of a multi-step upconversion lateral flow immunoassay using a 3D-printed actuation mechanism.

Raiko K, Naajarvi O, Ekman M, Koskela S, Soukka T, Martiskainen I Anal Bioanal Chem. 2024; 416(6):1517-1525.

PMID: 38280018 PMC: 10861389. DOI: 10.1007/s00216-024-05156-5.


Internet-of-medical-things integrated point-of-care biosensing devices for infectious diseases: Toward better preparedness for futuristic pandemics.

Parihar A, Yadav S, Sadique M, Ranjan P, Kumar N, Singhal A Bioeng Transl Med. 2023; 8(3):e10481.

PMID: 37206204 PMC: 10189496. DOI: 10.1002/btm2.10481.


References
1.
Martinez A, Phillips S, Wiley B, Gupta M, Whitesides G . FLASH: a rapid method for prototyping paper-based microfluidic devices. Lab Chip. 2008; 8(12):2146-50. PMC: 3065062. DOI: 10.1039/b811135a. View

2.
Martinez A, Phillips S, Whitesides G . Three-dimensional microfluidic devices fabricated in layered paper and tape. Proc Natl Acad Sci U S A. 2008; 105(50):19606-11. PMC: 2604941. DOI: 10.1073/pnas.0810903105. View

3.
Fenton E, Mascarenas M, Lopez G, Sibbett S . Multiplex lateral-flow test strips fabricated by two-dimensional shaping. ACS Appl Mater Interfaces. 2010; 1(1):124-9. DOI: 10.1021/am800043z. View