» Articles » PMID: 20227221

Evaluation of a New Third-generation ARCHITECT RHTLV-I/II Assay for Blood Screening and Diagnosis

Overview
Date 2010 Mar 16
PMID 20227221
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

In comparison to current on-market assays, the ARCHITECT rHTLV-I/II assay is the first fully automated assay that simultaneously detects human T-cell lymphotropic virus type I (HTLV-I) and type II (HTLV-II) in human serum and plasma. Specificity was assessed on 5646 blood donors and 692 clinical specimens. For sensitivity determination, 301 HTLV-I-positive and 105 HTLV-II-positive specimens were tested. Precision was between 3.98% and 4.31% coefficient of variation (CV) for specimens with 1 to 6 sample to cutoff. Specificity was 99.95% and 99.86% on specimens from blood donors and hospitalized patients, respectively. Sensitivity evaluation showed 100% detection on 301 HTLV-I and 105 HTLV-II specimens. HTLV-I and HTLV-II viruses are still circulating among general populations even in the low prevalence areas. To control the further spread of these retroviruses, we need to know that it is important to continue screening of blood. The performance evaluation data from this study demonstrate that the high throughput and fully automated ARCHITECT rHTLV-I/II chemiluminescence immunoassay effectively serves this purpose.

Citing Articles

Evaluation of human T-cell leukemia virus in vitro diagnostics using plasma specimens collected in Japan.

Kusagawa S, Kawana-Tachikawa A, Matsubayashi K, Sobata R, Hamaguchi I BMC Infect Dis. 2023; 23(1):418.

PMID: 37340346 PMC: 10283183. DOI: 10.1186/s12879-023-08402-w.


Anti-Human T-Cell Leukemia Virus Type 1 (HTLV-1) Antibody Assays in Cerebrospinal Fluid for the Diagnosis of HTLV-1-Associated Myelopathy/Tropical Spastic Paraparesis.

Kodama D, Tanaka M, Matsuzaki T, Nozuma S, Matsuura E, Takashima H J Clin Microbiol. 2021; 59(5).

PMID: 33658267 PMC: 8091837. DOI: 10.1128/JCM.03230-20.


Novel Genetic Constructs for Production of Recombinant HTLV-1/2 Antigens and Evaluation of Their Reactivity to Plasma Samples from HTLV-1-Infected Patients.

Oliveira U, Santos F, Galvao-Castro B, Krieger M, Zanchin N J Clin Microbiol. 2021; 59(4).

PMID: 33504592 PMC: 8092729. DOI: 10.1128/JCM.02701-20.


Pregnancy does not adversely impact diagnostic tests for HTLV-1/2 infection.

Rosadas C, Tosswill J, Tedder R, Taylor G PLoS Negl Trop Dis. 2019; 13(9):e0007736.

PMID: 31513603 PMC: 6764679. DOI: 10.1371/journal.pntd.0007736.


Evaluation of Elecsys HTLV-I/II assay in comparison with ARCHITECT rHTLV-I/II assay with Korean samples.

Yun S, Kim S, Sohn J, Cho Y J Clin Lab Anal. 2019; 33(6):e22909.

PMID: 31059152 PMC: 6642323. DOI: 10.1002/jcla.22909.