» Articles » PMID: 20196193

Systematic Investigation of Ion Suppression and Enhancement Effects of Fourteen Stable-isotope-labeled Internal Standards by Their Native Analogues Using Atmospheric-pressure Chemical Ionization and Electrospray Ionization and the Relevance For...

Overview
Specialty Chemistry
Date 2010 Mar 3
PMID 20196193
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

In clinical and forensic toxicology, multi-analyte procedures are very useful to quantify drugs and poisons of different classes in one run. For liquid chromatographic/tandem mass spectrometric (LC/MS/MS) multi-analyte procedures, often only a limited number of stable-isotope-labeled internal standards (SIL-ISs) are available. If an SIL-IS is used for quantification of other analytes, it must be excluded that the co-eluting native analyte influences its ionization. Therefore, the effect of ion suppression and enhancement of fourteen SIL-ISs caused by their native analogues has been studied. It could be shown that the native analyte concentration influenced the extent of ion suppression and enhancement effects leading to more suppression with increasing analyte concentration especially when electrospray ionization (ESI) was used. Using atmospheric-pressure chemical ionization (APCI), methanolic solution showed mainly enhancement effects, whereas no ion suppression and enhancement effect, with one exception, occurred when plasma extracts were used under these conditions. Such differences were not observed using ESI. With ESI, eleven SIL-ISs showed relevant suppression effects, but only one analyte showed suppression effects when APCI was used. The presented study showed that ion suppression and enhancement tests using matrix-based samples of different sources are essential for the selection of ISs, particularly if used for several analytes to avoid incorrect quantification. In conclusion, only SIL-ISs should be selected for which no suppression and enhancement effects can be observed. If not enough ISs are free of ionization interferences, a different ionization technique should be considered.

Citing Articles

Signal Suppression in LC-ESI-MS/MS from Concomitant Medications and Its Impact on Quantitative Studies: An Example Using Metformin and Glyburide.

Liu J, Jiang F, Lu Z, Zhang C, Liu P, Huang M Molecules. 2023; 28(2).

PMID: 36677804 PMC: 9862991. DOI: 10.3390/molecules28020746.


Closing the gap - development of an analytical methodology using volumetric absorptive microsampling of finger prick blood followed by LC-HRMS/MS for adherence monitoring of antihypertensive drugs.

Jacobs C, Kunz M, Mahfoud F, Wagmann L, Meyer M Anal Bioanal Chem. 2022; 415(1):167-177.

PMID: 36318313 PMC: 9816235. DOI: 10.1007/s00216-022-04394-9.


Quantifying Precision Loss in Targeted Metabolomics Based on Mass Spectrometry and Nonmatching Internal Standards.

Ulvik A, McCann A, Midttun O, Meyer K, Godfrey K, Ueland P Anal Chem. 2021; 93(21):7616-7624.

PMID: 34014078 PMC: 7611570. DOI: 10.1021/acs.analchem.1c00119.


Development of Tandem Mass Tag Labeling Method for Lipid Molecules Containing Carboxy and Phosphate Groups, and Their Stability in Human Serum.

Tokuoka S, Kita Y, Sato M, Shimizu T, Yatomi Y, Oda Y Metabolites. 2021; 11(1).

PMID: 33396791 PMC: 7824108. DOI: 10.3390/metabo11010019.


Simultaneous quantification of ticagrelor and its active metabolite, AR-C124910XX, in human plasma by liquid chromatography-tandem mass spectrometry: Applications in steady-state pharmacokinetics in patients.

Chae S, Min K, Lee C, Huang Z, Chang M, Bae S Transl Clin Pharmacol. 2020; 27(3):98-106.

PMID: 32055590 PMC: 6989238. DOI: 10.12793/tcp.2019.27.3.98.