» Articles » PMID: 20179760

C-reactive Protein, Erythrocyte Sedimentation Rate and Orthopedic Implant Infection

Abstract

Background: C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) have been shown to be useful for diagnosis of prosthetic hip and knee infection. Little information is available on CRP and ESR in patients undergoing revision or resection of shoulder arthroplasties or spine implants.

Methods/results: We analyzed preoperative CRP and ESR in 636 subjects who underwent knee (n=297), hip (n=221) or shoulder (n=64) arthroplasty, or spine implant (n=54) removal. A standardized definition of orthopedic implant-associated infection was applied. Receiver operating curve analysis was used to determine ideal cutoff values for differentiating infected from non-infected cases. ESR was significantly different in subjects with aseptic failure infection of knee (median 11 and 53.5 mm/h, respectively, p=<0.0001) and hip (median 11 and 30 mm/h, respectively, p=<0.0001) arthroplasties and spine implants (median 10 and 48.5 mm/h, respectively, p=0.0033), but not shoulder arthroplasties (median 10 and 9 mm/h, respectively, p=0.9883). Optimized ESR cutoffs for knee, hip and shoulder arthroplasties and spine implants were 19, 13, 26, and 45 mm/h, respectively. Using these cutoffs, sensitivity and specificity to detect infection were 89 and 74% for knee, 82 and 60% for hip, and 32 and 93% for shoulder arthroplasties, and 57 and 90% for spine implants. CRP was significantly different in subjects with aseptic failure and infection of knee (median 4 and 51 mg/l, respectively, p<0.0001), hip (median 3 and 18 mg/l, respectively, p<0.0001), and shoulder (median 3 and 10 mg/l, respectively, p=0.01) arthroplasties, and spine implants (median 3 and 20 mg/l, respectively, p=0.0011). Optimized CRP cutoffs for knee, hip, and shoulder arthroplasties, and spine implants were 14.5, 10.3, 7, and 4.6 mg/l, respectively. Using these cutoffs, sensitivity and specificity to detect infection were 79 and 88% for knee, 74 and 79% for hip, and 63 and 73% for shoulder arthroplasties, and 79 and 68% for spine implants.

Conclusion: CRP and ESR have poor sensitivity for the diagnosis of shoulder implant infection. A CRP of 4.6 mg/l had a sensitivity of 79 and a specificity of 68% to detect infection of spine implants.

Citing Articles

The diagnostic accuracy of blood C-reactive protein and erythrocyte sedimentation rate in periprosthetic joint infections - A 10-year analysis of 1510 revision hip and knee arthroplasties from a single orthopaedic center.

Grzelecki D, Kocon M, Mazur R, Grajek A, Kowalczewski J J Orthop Surg Res. 2025; 20(1):276.

PMID: 40082905 PMC: 11907961. DOI: 10.1186/s13018-025-05531-7.


The value of an open biopsy in the diagnosis of periprosthetic joint infection.

Da Silva A, Moverman M, Soule S, Joyce C, Tashjian R, Chalmers P JSES Int. 2025; 8(6):1228-1233.

PMID: 39822830 PMC: 11733564. DOI: 10.1016/j.jseint.2024.07.010.


strains associated with bone prosthesis infections cannot evade the host immune system.

Thoraval L, Tang-Fichaux M, Guillaume C, Varin-Simon J, Dumortier C, Sergheraert J Front Immunol. 2024; 15:1468709.

PMID: 39664373 PMC: 11632127. DOI: 10.3389/fimmu.2024.1468709.


Analysis of Serum and Synovial Inflammatory Markers in Periprosthetic Joint Infections: A Narrative Review.

Yadav A, Murhekar S, Cinar E Cureus. 2024; 16(11):e72821.

PMID: 39493345 PMC: 11528397. DOI: 10.7759/cureus.72821.


Utility of Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry in Periprosthetic Joint Infection Diagnosis.

Sandu E, Cursaru A, Iordache S, Serban B, Costache M, Cirstoiu C Cureus. 2024; 16(10):e70650.

PMID: 39483552 PMC: 11527459. DOI: 10.7759/cureus.70650.


References
1.
Shih L, Wu J, Yang D . Erythrocyte sedimentation rate and C-reactive protein values in patients with total hip arthroplasty. Clin Orthop Relat Res. 1987; (225):238-46. View

2.
Hahn F, Zbinden R, Min K . Late implant infections caused by Propionibacterium acnes in scoliosis surgery. Eur Spine J. 2005; 14(8):783-8. PMC: 3489259. DOI: 10.1007/s00586-004-0854-6. View

3.
Feldman D, Lonner J, Desai P, Zuckerman J . The role of intraoperative frozen sections in revision total joint arthroplasty. J Bone Joint Surg Am. 1995; 77(12):1807-13. DOI: 10.2106/00004623-199512000-00003. View

4.
Kanafani Z, Sexton D, Pien B, Varkey J, Basmania C, Kaye K . Postoperative joint infections due to Propionibacterium species: a case-control study. Clin Infect Dis. 2009; 49(7):1083-5. DOI: 10.1086/605577. View

5.
Schinsky M, Della Valle C, Sporer S, Paprosky W . Perioperative testing for joint infection in patients undergoing revision total hip arthroplasty. J Bone Joint Surg Am. 2008; 90(9):1869-75. DOI: 10.2106/JBJS.G.01255. View