Background: Plasma clearance of iohexol (PCI) is becoming a commonly used standard tool in many clinical trials to evaluate the glomerular filtration rate (GFR). However, most studies performing PCI use only early plasma samples (2, 3, and 4 hr). This study aims to evaluate the role of early and late plasma sampling in the precision of PCI calculation in transplant recipients.

Methods: We evaluated 342 renal transplant recipients for both renal clearance (RC) and plasma clearance, using iohexol and six blood samples (2, 3, 4, 5, 6, and 24 hr). Patients were divided into three subgroups according to RC: <30, 30 to 60, and >60 mL/min/1.75 m(2).

Results: A simplified technique using early plasma samples overestimated GFR with a mean difference between plasma clearance and RC of 53.3%, 25.7%, and 12.5% for the three subgroups, respectively. This difference decreased to 8.8%, 6.3%, and 5.5%, respectively, when the 24-hr sample was included in plasma clearance calculation.

Conclusion: These results demonstrate that GFR evaluation by PCI in renal transplant recipients requires a late plasma sample.

Citing Articles

Determination of glomerular filtration rate "en passant" after high doses of iohexol for computed tomography in intensive care medicine-a proof of concept.

Dejaco A, Dorn C, Paal M, Gruber M, Graf B, Kees M Front Pharmacol. 2024; 15:1346343.

PMID: 38362152 PMC: 10867190. DOI: 10.3389/fphar.2024.1346343.


Diverse protocols for measuring glomerular filtration rate using iohexol clearance.

Mohamed A, Bokenkamp A, Cavalier E, Delanaye P, Ebert N, van Londen M Nephrol Dial Transplant. 2024; 39(6):1037-1039.

PMID: 38228403 PMC: 11210064. DOI: 10.1093/ndt/gfae006.


Assessment of Iohexol Serum Clearance by LC-MS/MS with Isotopically Labeled Internal Standard.

Jin Z, Bertholf R, Yi X Methods Mol Biol. 2023; 2737:319-327.

PMID: 38036833 DOI: 10.1007/978-1-0716-3541-4_29.


Accuracy-Based Glomerular Filtration Rate Assessment by Plasma Iohexol Clearance in Kidney Transplant Donors.

Jin Z, Huang R, Christensen P, Bertholf R, Yi X J Clin Med. 2023; 12(18).

PMID: 37762993 PMC: 10532236. DOI: 10.3390/jcm12186054.


Improved correction formulas to estimate iohexol clearance from simple models.

Dong Q, Fuhr U, Schaeffner E, van der Giet M, Ebert N, Taubert M Eur J Clin Pharmacol. 2023; 79(9):1215-1217.

PMID: 37422532 PMC: 10427699. DOI: 10.1007/s00228-023-03535-y.