» Articles » PMID: 20152992

Predictors of Low Cardiac Output Syndrome After Isolated Mitral Valve Surgery

Overview
Date 2010 Feb 16
PMID 20152992
Citations 37
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Low cardiac output syndrome is defined as the need for a postoperative intra-aortic balloon pump or inotropic support for longer than 30 minutes in the intensive care unit. Mitral valve surgery is increasingly being performed in high-risk patients who might require mechanical circulatory support for low cardiac output syndrome. Therefore the aim of this study was to identify the preoperative predictors of low cardiac output syndrome after mitral valve surgery.

Methods: We conducted a retrospective review of data prospectively entered into an institutional database. Between 1990 and February 2008, 3039 patients underwent isolated mitral valve surgery with or without coronary bypass surgery. The independent predictors of low cardiac output syndrome and operative mortality were determined by means of stepwise logistic regression analysis.

Results: The overall prevalence of low cardiac output syndrome was 7%. The independent predictors of low cardiac output syndrome were urgency of the operation (odds ratio, 2.9), earlier year of operation (odds ratio, 2.4), left ventricular ejection fraction of less than 40% (odds ratio, 2.1), New York Heart Association class IV (odds ratio, 2), body surface area of 1.7 m(2) or less (odds ratio, 1.6), ischemic mitral valve pathology (odds ratio, 1.6), and cardiopulmonary bypass time (odds ratio, 1.02). The operative mortality was higher in patients with low cardiac output syndrome (30% vs 1.3%, P < .001). Overall operative mortality was 3.4%. The independent predictors of mortality were urgency of the operation (odds ratio, 7.1), renal failure (odds ratio, 4.3), nonuse of polytetrafluoroethylene sutures (Gore-Tex; W. L. Gore & Associates, Inc, Austin, Tex; odds ratio, 2.1), any reoperative surgical intervention (odds ratio, 1.8), increasing age (odds ratio, 1.03), and cardiopulmonary bypass time (odds ratio, 1.02).

Conclusions: Low cardiac output syndrome is associated with significantly increased morbidity and mortality. Novel strategies to preserve renal function, optimization of pre-existing heart failure symptoms, and use of artificial polytetrafluoroethylene sutures might reduce the incidence of low cardiac output syndrome and lead to improved results after mitral valve surgery.

Citing Articles

Rapid-recovery protocol for minimally invasive mitral valve repair.

Brown A, Hassanabad A, Moen J, Wiens K, Gregory A, Parhar K JTCVS Open. 2025; 22():49-60.

PMID: 39780802 PMC: 11704579. DOI: 10.1016/j.xjon.2024.08.006.


Management of Post-cardiotomy Shock.

Hall E, Papolos A, Miller P, Barnett C, Kenigsberg B US Cardiol. 2024; 18:e11.

PMID: 39494414 PMC: 11526484. DOI: 10.15420/usc.2024.16.


Relationship between Preoperative Red Cell Distribution Width and Prolonged Postoperative Use of Catecholamines in Minimally Invasive Mitral Valve Surgery Patients: A Retrospective Cohort Study.

Carrara A, Peluso L, Baccanelli F, Parrinello M, Santarpino G, Giroletti L J Clin Med. 2024; 13(19).

PMID: 39407797 PMC: 11476661. DOI: 10.3390/jcm13195736.


Predictors of low cardiac output syndrome after combined mitral and tricuspid valve surgery.

Labaste F, Lavie-Badie Y, Bouchau R, Boyere L, Sanchez-Verlaan P, Gonzalez H Front Cardiovasc Med. 2024; 11:1452820.

PMID: 39371394 PMC: 11449694. DOI: 10.3389/fcvm.2024.1452820.


Neutrophil-to-lymphocyte ratio as a predictor of low cardiac output syndrome after open heart surgery in children with congenital heart disease.

Laila D, Perdana A, Permatasari R, Kadim M, Advani N, Supriyatno B Narra J. 2024; 4(2):e736.

PMID: 39280269 PMC: 11391973. DOI: 10.52225/narra.v4i2.736.