Model-based Ultrasound Temperature Visualization During and Following HIFU Exposure

Overview
Specialty Radiology
Date 2010 Feb 2
PMID 20113861
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

This paper describes the application of signal processing techniques to improve the robustness of ultrasound feedback for displaying changes in temperature distribution in treatment using high-intensity focused ultrasound (HIFU), especially at the low signal-to-noise ratios that might be expected in in vivo abdominal treatment. Temperature estimation is based on the local displacements in ultrasound images taken during HIFU treatment, and a method to improve robustness to outliers is introduced. The main contribution of the paper is in the application of a Kalman filter, a statistical signal processing technique, which uses a simple analytical temperature model of heat dispersion to improve the temperature estimation from the ultrasound measurements during and after HIFU exposure. To reduce the sensitivity of the method to previous assumptions on the material homogeneity and signal-to-noise ratio, an adaptive form is introduced. The method is illustrated using data from HIFU exposure of ex vivo bovine liver. A particular advantage of the stability it introduces is that the temperature can be visualized not only in the intervals between HIFU exposure but also, for some configurations, during the exposure itself.

Citing Articles

Multiscale photoacoustic tomography using reversibly switchable thermochromics.

Ma C, Kuang X, Chen M, Menozzi L, Jiang L, Zhou Q J Biomed Opt. 2023; 28(8):082804.

PMID: 36817549 PMC: 9932525. DOI: 10.1117/1.JBO.28.8.082804.


Focused Ultrasound for Neuromodulation.

Darrow D Neurotherapeutics. 2018; 16(1):88-99.

PMID: 30488340 PMC: 6361056. DOI: 10.1007/s13311-018-00691-3.


Calibration and Evaluation of Ultrasound Thermography Using Infrared Imaging.

Hsiao Y, Deng C Ultrasound Med Biol. 2015; 42(2):503-17.

PMID: 26547634 PMC: 4698082. DOI: 10.1016/j.ultrasmedbio.2015.09.021.


Thermometry and ablation monitoring with ultrasound.

Lewis M, Staruch R, Chopra R Int J Hyperthermia. 2015; 31(2):163-81.

PMID: 25753369 PMC: 4467963. DOI: 10.3109/02656736.2015.1009180.


An approach for the visualization of temperature distribution in tissues according to changes in ultrasonic backscattered energy.

Xia J, Li Q, Liu H, Chen W, Tsui P Comput Math Methods Med. 2013; 2013:682827.

PMID: 24260041 PMC: 3821909. DOI: 10.1155/2013/682827.