Bending Properties of Superelastic and Nonsuperelastic Nickel-titanium Orthodontic Wires

Overview
Publisher Elsevier
Specialty Dentistry
Date 1991 Apr 1
PMID 2008890
Citations 19
Authors
Affiliations
Soon will be listed here.
Abstract

Cantilever bending properties were evaluated for several clinically popular sizes of three superelastic and three nonsuperelastic brands of nickel-titanium orthodontic wires in the as-received condition, and for 0.016-inch diameter wires after heat treatment at 500 degrees and at 600 degrees C, for 10 minutes and for 2 hours. A torque meter apparatus was used for the bending experiments, and the specimen test-span length was 1/4 inch (6 mm). In general, the bending properties were similar for the three brands of superelastic wires and for the three brands of nonsuperelastic wires. For the three brands of superelastic wires, heat treatment at 500 degrees C for 10 minutes had minimal effect on the bending plots, whereas heat treatment at 500 degrees C for 2 hours caused decreases in the average superelastic bending moment during deactivation; heat treatment at 600 degrees C resulted in loss of superelasticity. The bending properties for the three brands of nonsuperelastic wires were only slightly affected by these heat treatments. The differences in the bending properties and heat treatment responses are attributed to the relative proportions of the austenitic and martensitic forms of nickel-titanium alloy (NiTi) in the microstructures of the wire alloys.

Citing Articles

Thermal behavior and cyclic fatigue resistance of three contemporary NiTi heat-treated single-file systems: metallurgical study.

Alsofi L, Al-Marshadi M, AbuHaimed T, Al-Habib M, Saif R, Bukhari S BMC Oral Health. 2025; 25(1):338.

PMID: 40038622 PMC: 11881276. DOI: 10.1186/s12903-025-05708-w.


The effect of different clinical recycling methods on load deflection properties of super-elastic and thermal nickel-titanium orthodontic arch wires: A comparative assessment.

Shukla P, Kapoor S, Jaiswal R, Sharma V, Shashtri D, Bhagchandani J J Orthod Sci. 2024; 13:27.

PMID: 39450219 PMC: 11500735. DOI: 10.4103/jos.jos_200_23.


The effect of autoclave cycles on the mechanical properties and surface roughness of NiTi archwires: ex-vivo study.

Shahawi A, Aboalnaga A BMC Oral Health. 2024; 24(1):1284.

PMID: 39448972 PMC: 11515396. DOI: 10.1186/s12903-024-04877-4.


The Effect of Intraoral Thermal Changes on the Mechanical Behavior of Nickel-Titanium Wires: An In-Vitro Study.

Al-Horini O, Masaes M, Baba F, Hajeer M, Almulla S, Mousa M Cureus. 2024; 16(10):e72207.

PMID: 39445040 PMC: 11498319. DOI: 10.7759/cureus.72207.


Influence of distal-end heat treatment in the properties of heat-activated NiTi archwires.

de Oliveira Abrahao J, Hermont Cancado R, Franca E, Santos L, Resende P, Weidenbach Degrazia F J Orofac Orthop. 2024; .

PMID: 39190140 DOI: 10.1007/s00056-024-00547-w.