» Articles » PMID: 20059241

Parametric Image Reconstruction Using the Discrete Cosine Transform for Optical Tomography

Overview
Journal J Biomed Opt
Date 2010 Jan 12
PMID 20059241
Citations 2
Authors
Affiliations
Soon will be listed here.
Abstract

It is well known that the inverse problem in optical tomography is highly ill-posed. The image reconstruction process is often unstable and nonunique, because the number of the boundary measurements data is far fewer than the number of the unknown parameters to be reconstructed. To overcome this problem, one can either increase the number of measurement data (e.g., multispectral or multifrequency methods), or reduce the number of unknowns (e.g., using prior structural information from other imaging modalities). We introduce a novel approach for reducing the unknown parameters in the reconstruction process. The discrete cosine transform (DCT), which has long been used in image compression, is here employed to parameterize the reconstructed image. In general, only a few DCT coefficients are needed to describe the main features in an optical tomographic image. Thus, the number of unknowns in the image reconstruction process can be drastically reduced. We show numerical and experimental examples that illustrate the performance of the new algorithm as compared to a standard model-based iterative image reconstructions scheme. We especially focus on the influence of initial guesses and noise levels on the reconstruction results.

Citing Articles

Genetic algorithm based image reconstruction applying the digital holography process with the Discrete Orthonormal Stockwell Transform technique for diagnosis of COVID-19.

Ustabas Kaya G, Onur T Comput Biol Med. 2022; 148:105934.

PMID: 35961086 PMC: 9344740. DOI: 10.1016/j.compbiomed.2022.105934.


Flexible optical imaging band system for the assessment of arthritis in patients with systemic lupus erythematosus.

Kim Y, Marone A, Tang W, Gartshteyn Y, Kim H, Askanase A Biomed Opt Express. 2021; 12(3):1651-1665.

PMID: 33796379 PMC: 7984785. DOI: 10.1364/BOE.415575.

References
1.
Boas D, Dale A, Franceschini M . Diffuse optical imaging of brain activation: approaches to optimizing image sensitivity, resolution, and accuracy. Neuroimage. 2004; 23 Suppl 1:S275-88. DOI: 10.1016/j.neuroimage.2004.07.011. View

2.
Huang M, Zhu Q . Dual-mesh optical tomography reconstruction method with a depth correction that uses a priori ultrasound information. Appl Opt. 2004; 43(8):1654-62. PMC: 1538958. DOI: 10.1364/ao.43.001654. View

3.
Moon J, Mahon R, Duncan M, Reintjes J . Resolution limits for imaging through turbid media with diffuse light. Opt Lett. 2009; 18(19):1591-3. DOI: 10.1364/ol.18.001591. View

4.
Jacquin A . Image coding based on a fractal theory of iterated contractive image transformations. IEEE Trans Image Process. 1992; 1(1):18-30. DOI: 10.1109/83.128028. View

5.
Hall D, Hebden J, Delpy D . Evaluation of spatial resolution as a function of thickness for time-resolved optical imaging of highly scattering media. Med Phys. 1997; 24(3):361-8. DOI: 10.1118/1.597904. View