Exposure to Anaesthetic Trace Gases During General Anaesthesia: CobraPLA Vs. LMA Classic

Overview
Specialty Anesthesiology
Date 2010 Jan 9
PMID 20055764
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Background: To prospectively investigate the performance, sealing capacity and operating room (OR) staff exposure to waste anaesthetic gases during the use of the Cobra perilaryngeal airway (CobraPLA) compared with the laryngeal mask airway classic (LMA).

Methods: Sixty patients were randomly assigned to the CobraPLA or the LMA group. Insertion time, number of insertion attempts and airway leak pressures were assessed after induction of anaesthesia. Occupational exposure to nitrous oxide (N(2)O) and Sevoflurane (SEV) was measured at the anaesthetists' breathing zone and the patients' mouth using a photoacoustic infrared spectrometer.

Results: N(2)O waste gas concentrations differed significantly in the anaesthetist's breathing zone (11.7+/-7.2 p.p.m. in CobraPLA vs. 4.1+/-4.3 p.p.m. in LMA, P=0.03), whereas no difference could be shown in SEV concentrations. Correct CobraPLA positioning was possible in 28 out of 30 patients (more than one attempt necessary in five patients). Correct positioning of the LMA classic was possible in all 30 patients (more than one attempt in three patients). Peak airway pressure was higher in the CobraPLA group (16+/-3 vs. 14+/-2 cmH(2)O, P=0.01). The average leak pressure of the CobraPLA was 24+/-4 cmH(2)O, compared with 20+/-4 cmH(2)O of the LMA classic (P<0.001; all values means+/-SD).

Conclusion: Despite higher airway seal pressures, the CobraPLA caused higher intraoperative N(2)O trace concentrations in the anaesthetists' breathing zone.

Citing Articles

Bibliometric analysis of occupational exposure in operating room from 1973 to 2022.

Li C, Geng M, Li S, Li X, Li H, Yuan H J Occup Med Toxicol. 2024; 19(1):37.

PMID: 39375700 PMC: 11457397. DOI: 10.1186/s12995-024-00437-2.


Photoacoustic gas monitoring for anesthetic gas pollution measurements and its cross-sensitivity to alcoholic disinfectants.

Herzog-Niescery J, Steffens T, Bellgardt M, Breuer-Kaiser A, Gude P, Vogelsang H BMC Anesthesiol. 2019; 19(1):148.

PMID: 31399025 PMC: 6689173. DOI: 10.1186/s12871-019-0822-7.


Cobra-PLA provides higher oropharyngeal leak pressure than LMA-Classic and LMA-Unique: A meta-analysis with 22 studies.

Tan Y, Duan G, Chen Q, Chen F, Li H Medicine (Baltimore). 2019; 98(26):e15832.

PMID: 31261492 PMC: 6617436. DOI: 10.1097/MD.0000000000015832.


Waste anesthetic gas exposure and strategies for solution.

Deng H, Li F, Cai Y, Xu S J Anesth. 2018; 32(2):269-282.

PMID: 29404778 DOI: 10.1007/s00540-018-2448-1.


Does standing or sitting position of the anesthesiologist in the operating theatre influence sevoflurane exposure during craniotomies?.

Sarkany P, Tanko B, Simon E, Gal J, Fulesdi B, Molnar C BMC Anesthesiol. 2016; 16(1):120.

PMID: 27908275 PMC: 5134222. DOI: 10.1186/s12871-016-0284-0.