Background: Press-fit fixation of a tendon graft has been advocated to achieve tendon-to-bone healing.

Hypothesis: Fixation of hamstring tendon grafts with a porous bone scaffold limits bone tunnel enlargement compared with a biodegradable interference screw fixation.

Study Design: Randomized controlled trial; Level of evidence, 1. Methods Between 2005 and 2006, 20 patients (17 men, 3 women) with a primary reconstruction of the anterior cruciate ligament (ACL) were enrolled in this study. Patients were randomized to obtain graft fixation in the tibial tunnel either by means of an interference screw (I) or a press-fit fixation with a porous bone cylinder (P). At 3 months after surgery, a computed tomography (CT) scan of the knee was performed, and tunnel enlargement was analyzed in the coronal and sagittal planes for the proximal, middle, and distal thirds of the tunnel. After 6 months and 1 and 2 years, radiographs of the knee in the sagittal and coronal plane were analyzed for bone tunnel widening. The International Knee Documentation Committee (IKDC), Tegner, and Lysholm scores of both groups were compared after 1 and 2 years.

Results: The bone tunnel enlargement determined by CT was 106.9% + or - 10.9% for group P and 121.9% + or - 9.0% for group I (P < .02) in the anteroposterior (AP) plane and 102.8% + or - 15.2% versus 121.5% + or - 10.1% in the coronal plane (P <.01). The IKDC, Tegner, and Lysholm scores improved in both groups from preoperatively to postoperatively without significant differences between the 2 groups. There was a trend to higher knee stability in group P after 3 months (0.6 + or - 1.4 mm vs 1.8 + or - 1.5 mm; P = .08).

Conclusion: Both interference screw and a press-fit fixation lead to a high number of good or very good outcomes after ACL reconstruction. Tibial press-fit fixation decreases the amount of proximal bone tunnel enlargement.

Citing Articles

Osteoconductive Scaffold Placed at the Femoral Tunnel Aperture in Hamstring Tendon ACL Reconstruction: A Randomized Controlled Trial.

Gotschi T, Hodel S, Kuhne N, Bachmann E, Li X, Zimmermann S Orthop J Sports Med. 2023; 11(6):23259671231174478.

PMID: 37347015 PMC: 10280525. DOI: 10.1177/23259671231174478.


The safety and effectiveness comparison of Delta Medical's PEEK interface screw and Endobutton and that of Smith & Nephew's in arthroscopic anterior cruciate ligament reconstruction: A multicenter prospective double-blind randomized controlled....

Gao P, Yuan M, Xu Y, Wu Y, Lin X, Li Y Front Public Health. 2022; 10:1003591.

PMID: 36419987 PMC: 9676447. DOI: 10.3389/fpubh.2022.1003591.


Re-rupture rate and the post-surgical meniscal injury after anterior cruciate ligament reconstruction with the Press-Fit-Hybrid®-technique in comparison to the interference screw technique: a retrospective analysis of 200 patients with at least....

Volz R, Borchert G Arch Orthop Trauma Surg. 2022; 143(2):935-949.

PMID: 35290503 PMC: 9925573. DOI: 10.1007/s00402-022-04368-7.


Biomechanical Comparison of a Novel Tibial Fixation Technique Versus Interference Screw Fixation for ACL Reconstruction Using Soft Tissue Grafts.

Sun T, Zhang H Orthop J Sports Med. 2021; 9(8):23259671211028559.

PMID: 34458385 PMC: 8392818. DOI: 10.1177/23259671211028559.


Quadriceps and hamstring tendon autografts in ACL reconstruction yield comparably good results in a prospective, randomized controlled trial.

Horstmann H, Petri M, Tegtbur U, Felmet G, Krettek C, Jagodzinski M Arch Orthop Trauma Surg. 2021; 142(2):281-289.

PMID: 33742222 PMC: 8783919. DOI: 10.1007/s00402-021-03862-8.