» Articles » PMID: 20013273

Comparison of 4 Cm Z-axis and 16 Cm Z-axis Multidetector CT Perfusion

Overview
Journal Eur Radiol
Specialty Radiology
Date 2009 Dec 17
PMID 20013273
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: The aim of the study was to compare 4 cm with 16 cm Z-axis coverage in the assessment of brain CT perfusion (CTP) using. 320 slice multidetector CT METHODS: A retrospective non-randomised review of CTP performed on MD320 CT between September 2008 and January 2009 was undertaken. Two experienced readers reviewed the studies along with the 4 cm and 16 cm Z-axis CTP image data set. The outcome parameters assessed were the extent of the original finding, any additional findings and a change of diagnosis.

Results: 14 out of 27 patients were found to have abnormal CTP (mean age 58.1 years, 9 male). The 16 cm Z-axis increased the accuracy of the infarct core in 78% and ischaemic penumbra quantification in 100% of the cases. It also diagnosed additional infarcts in the same vascular territory in 28% of cases and in a different vascular territory in 14%.

Conclusions: The increased field of view with MD320 better defines the true extent of the infarct core and ischaemic penumbra. It also identified other areas of infarction that were not identified on the 4 cm Z-axis.

Citing Articles

The Potential Value of 320-Row Computed Tomography Angiography in Digital Subtraction Angiography-Negative Spontaneous Subarachnoid Hemorrhage Patients.

Wu S J Comput Assist Tomogr. 2022; 46(2):244-250.

PMID: 35081605 PMC: 8929304. DOI: 10.1097/RCT.0000000000001271.


Absolute cerebral blood flow: Assessment with a novel low-radiation-dose dynamic CT perfusion technique in a swine model.

Abbona P, Zhao Y, Hubbard L, Malkasian S, Flynn B, Molloi S J Neuroradiol. 2021; 49(2):173-179.

PMID: 34634295 PMC: 9231667. DOI: 10.1016/j.neurad.2021.09.003.


When a Slice Is Not Enough! Comparison of Whole-Brain versus Standard Limited-Slice Perfusion Computed Tomography in Patients with Severe Traumatic Brain Injury.

Cooper S, Bendinelli C, Bivard A, Parsons M, Balogh Z J Clin Med. 2019; 8(5).

PMID: 31108945 PMC: 6571909. DOI: 10.3390/jcm8050701.


Perfusion CT in acute stroke: effectiveness of automatically-generated colour maps.

Ukmar M, Degrassi F, Pozzi Mucelli R, Neri F, Pozzi Mucelli F, Cova M Br J Radiol. 2017; 90(1072):20150472.

PMID: 28328241 PMC: 5605056. DOI: 10.1259/bjr.20150472.


Quantifying reperfusion of the ischemic region on whole-brain computed tomography perfusion.

Lin L, Cheng X, Bivard A, Levi C, Dong Q, Parsons M J Cereb Blood Flow Metab. 2016; 37(6):2125-2136.

PMID: 27461903 PMC: 5464706. DOI: 10.1177/0271678X16661338.


References
1.
Wintermark M, Smith W, Ko N, Quist M, Schnyder P, Dillon W . Dynamic perfusion CT: optimizing the temporal resolution and contrast volume for calculation of perfusion CT parameters in stroke patients. AJNR Am J Neuroradiol. 2004; 25(5):720-9. PMC: 7974477. View

2.
Roberts H, Roberts T, Smith W, Lee T, Fischbein N, Dillon W . Multisection dynamic CT perfusion for acute cerebral ischemia: the "toggling-table" technique. AJNR Am J Neuroradiol. 2001; 22(6):1077-80. PMC: 7974776. View

3.
Latchaw R, Yonas H, Hunter G, Yuh W, Ueda T, Sorensen A . Guidelines and recommendations for perfusion imaging in cerebral ischemia: A scientific statement for healthcare professionals by the writing group on perfusion imaging, from the Council on Cardiovascular Radiology of the American Heart Association. Stroke. 2003; 34(4):1084-104. DOI: 10.1161/01.STR.0000064840.99271.9E. View

4.
Eastwood J, Lev M, Wintermark M, Fitzek C, Barboriak D, DeLong D . Correlation of early dynamic CT perfusion imaging with whole-brain MR diffusion and perfusion imaging in acute hemispheric stroke. AJNR Am J Neuroradiol. 2003; 24(9):1869-75. PMC: 7976307. View

5.
Ezzeddine M, Lev M, McDonald C, Rordorf G, Oliveira-Filho J, Aksoy F . CT angiography with whole brain perfused blood volume imaging: added clinical value in the assessment of acute stroke. Stroke. 2002; 33(4):959-66. DOI: 10.1161/hs0402.105388. View