This work explores slice profile effects in 2D slice-selective gradient-echo MRI of hyperpolarized nuclei. Two different sequences were investigated: a Spoiled Gradient Echo sequence with variable flip angle (SPGR-VFA) and a balanced Steady-State Free Precession (SSFP) sequence. It is shown that in SPGR-VFA the distribution of flip angles across the slice present in any realistically shaped radiofrequency (RF) pulse leads to large excess signal from the slice edges in later RF views, which results in an undesired non-constant total transverse magnetization, potentially exceeding the initial value by almost 300% for the last RF pulse. A method to reduce this unwanted effect is demonstrated, based on dynamic scaling of the slice selection gradient. SSFP sequences with small to moderate flip angles (<40 degrees ) are also shown to preserve the slice profile better than the most commonly used SPGR sequence with constant flip angle (SPGR-CFA). For higher flip angles, the slice profile in SSFP evolves in a manner similar to SPGR-CFA, with depletion of polarization in the center of the slice.

Citing Articles

Synthetic MRI for Radiotherapy Planning for Brain and Prostate Cancers: Phantom Validation and Patient Evaluation.

Gouel P, Hapdey S, Dumouchel A, Gardin I, Torfeh E, Hinault P Front Oncol. 2022; 12:841761.

PMID: 35515105 PMC: 9065558. DOI: 10.3389/fonc.2022.841761.


In vivo methods and applications of xenon-129 magnetic resonance.

Marshall H, Stewart N, Chan H, Rao M, Norquay G, Wild J Prog Nucl Magn Reson Spectrosc. 2021; 122:42-62.

PMID: 33632417 PMC: 7933823. DOI: 10.1016/j.pnmrs.2020.11.002.


Measuring pulmonary gas exchange using compartment-selective xenon-polarization transfer contrast (XTC) MRI.

Amzajerdian F, Ruppert K, Hamedani H, Baron R, Xin Y, Loza L Magn Reson Med. 2020; 85(5):2709-2722.

PMID: 33283943 PMC: 7902388. DOI: 10.1002/mrm.28626.


Slice profile effects on quantitative analysis of hyperpolarized pyruvate.

Walker C, Gordon J, Xu Z, Michel K, Li L, Larson P NMR Biomed. 2020; 33(10):e4373.

PMID: 32743881 PMC: 7484340. DOI: 10.1002/nbm.4373.


Ultra-high spatial resolution BOLD fMRI in humans using combined segmented-accelerated VFA-FLEET with a recursive RF pulse design.

Berman A, Grissom W, Witzel T, Nasr S, Park D, Setsompop K Magn Reson Med. 2020; 85(1):120-139.

PMID: 32705723 PMC: 7722122. DOI: 10.1002/mrm.28415.