» Articles » PMID: 19969209

Visual Function After Bilateral Implantation of Apodized Diffractive Aspheric Multifocal Intraocular Lenses with a +3.0 D Addition

Overview
Specialty Ophthalmology
Date 2009 Dec 9
PMID 19969209
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To evaluate visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses (IOLs) with a +3.0 diopter addition (add) power.

Setting: Multicenter study at 5 European sites.

Methods: Five surgeons prospectively enrolled patients to receive bilateral implantation of AcrySof IQ ReSTOR SN6AD1 IOLs. Assessments included defocus testing, uncorrected and corrected distance visual acuities at various distances, and patient questionnaires.

Results: Ninety-three patients were enrolled. The mean distance-corrected visual acuities at far, intermediate, and near distances were significantly better postoperatively. At 6 months, uncorrected visual acuity (logMAR) was -0.03 +/- 0.13 (SD) at 4 m, 0.20 +/- 0.14 at 70 cm, 0.13 +/- 0.15 at 60 cm, 0.05 +/- 0.18 at 50 cm, and 0.04 +/- 0.11 at 40 cm. The mean patient-preferred near distance was 41 +/- 4 cm, at which distance the mean visual acuity was -0.01 +/- 0.11 logMAR. The defocus curve had a plateau of optimum near vision from 40 to 50 cm. Postoperatively, patients reported having minimal to no difficulty with 22 of 27 visual disturbances or visual activities; the other 5 items were ranked minimally to moderately difficult. The mean patient satisfaction with vision was 8.3 +/- 1.6 (out of 10); 88% of patients were spectacle independent.

Conclusions: Bilateral apodized diffractive aspheric multifocal IOLs with a +3.0 D add provided a broad range of optimum near vision, good intermediate visual acuity, and low rates of visual disturbances. Patients were highly satisfied with their vision, and 88% were spectacle independent.

Citing Articles

Association of Patient Satisfaction with Cataract Grading in Five Types of Multifocal IOLs.

Niazi S, Gatzioufas Z, Dhubhghaill S, Moshirfar M, Faramarzi A, Mohammadi F Adv Ther. 2023; 41(1):231-245.

PMID: 37884810 DOI: 10.1007/s12325-023-02698-5.


Long term visual outcomes in cataract surgery with bilateral implantation of the Extended Depth of Focus Intraocular Lens - Mini Well Ready type.

Nicula C, Rednik A, Nicula A, Bulboaca A, Nicula D, Horvath K Rom J Ophthalmol. 2023; 66(4):317-325.

PMID: 36589331 PMC: 9773115. DOI: 10.22336/rjo.2022.58.


Clinical outcomes of topography-guided femtosecond laser-assisted in situ keratomileusis after multifocal intraocular lens implantation.

Shin E, Yoo Y, Choi S, Han S, Lim D, Yoon G Sci Rep. 2020; 10(1):10666.

PMID: 32606388 PMC: 7326976. DOI: 10.1038/s41598-020-67726-8.


Comparative Analysis of Visual Performance and Optical Quality with a Rotationally Asymmetric Multifocal Intraocular Lens and an Apodized Diffractive Multifocal Intraocular Lens.

Wang X, Tu H, Wang Y J Ophthalmol. 2020; 2020:7923045.

PMID: 32377423 PMC: 7189321. DOI: 10.1155/2020/7923045.


Innovative trifocal (quadrifocal) presbyopia-correcting IOLs: 1-year outcomes from an international multicenter study.

Kohnen T, Marchini G, Alfonso J, Bala C, Cochener B, Martinez A J Cataract Refract Surg. 2020; 46(8):1142-1148.

PMID: 32358415 PMC: 7688079. DOI: 10.1097/j.jcrs.0000000000000232.