» Articles » PMID: 19963520

Validation of a Graphic Measurement of Heart Rate Variability to Assess Analgesia/nociception Balance During General Anesthesia

Overview
Date 2009 Dec 8
PMID 19963520
Citations 36
Authors
Affiliations
Soon will be listed here.
Abstract

The optimization of analgesic drugs delivery during general anesthesia (GA) requires to evaluate the pain/analgesia balance. Heart Rate Variability (HRV) analysis has long been shown to measure the autonomic nervous system tone, which is strongly influenced by anesthetic drugs. Power spectrum measurements are widely used to assess HRV low (LF) and high frequency (HF) ranges, related to the sympathetic and parasympathetic systems. We have developed an original graphic measurement technique (EnvTOT) of the ventilatory influence on the RR series. Measurements on simulated RR series showed that the graphic assessment is independent from respiratory rate, while LF and HF spectral measurements are over- and underestimated for respiratory rates lower than 12 cycles min Clinical measurements on 49 patients during GA showed that normalized HF power was strongly related to hemodynamic responsiveness during GA, and was strongly correlated with normalized EnvTOT measurements. A real time computation of the RR series could therefore help medical staff to anticipate hemodynamic responsiveness and the analgesia/nociception balance during GA.

Citing Articles

A Multimodal Deep Learning Approach to Intraoperative Nociception Monitoring: Integrating Electroencephalogram, Photoplethysmography, and Electrocardiogram.

Abdel Deen O, Fan S, Shieh J Sensors (Basel). 2025; 25(4).

PMID: 40006379 PMC: 11859842. DOI: 10.3390/s25041150.


Comparison of Perioperative Analgesic Efficacy of Lidocaine Intratesticular Block and Spermatic Cord Instillation in Feline Castration.

Makpunpol T, Chanrobru Y, Thanapaisal P, Kuropakaranan M, Wipoosak P, Seesupa S Vet Sci. 2025; 12(2).

PMID: 40005869 PMC: 11861551. DOI: 10.3390/vetsci12020111.


Monitoring surgical nociception using multisensor physiological models.

Subramanian S, Tseng B, Del Carmen M, Goodman A, Dahl D, Barbieri R Proc Natl Acad Sci U S A. 2024; 121(40):e2319316121.

PMID: 39316050 PMC: 11459174. DOI: 10.1073/pnas.2319316121.


Use of Infrared Thermography and Heart Rate Variability to Evaluate Autonomic Activity in Domestic Animals.

Ghezzi M, Ceriani M, Dominguez-Oliva A, Lendez P, Olmos-Hernandez A, Casas-Alvarado A Animals (Basel). 2024; 14(9).

PMID: 38731370 PMC: 11083326. DOI: 10.3390/ani14091366.


Analgesia nociception index is an indicator of laparoscopic trocar insertion-induced transient nociceptive stimuli.

Liu J, Wang Z, Huang W, Cheng N, Chen W, Wu W Open Med (Wars). 2024; 19(1):20240933.

PMID: 38681026 PMC: 11048736. DOI: 10.1515/med-2024-0933.