Square Wave Voltammetry Versus Electrochemical Impedance Spectroscopy As a Rapid Detection Technique at Electrochemical Immunosensors
Overview
Biotechnology
Affiliations
Square wave voltammetry (SWV) was compared to electrochemical impedance spectroscopy (EIS) in developing a label-free electrochemical immunosensor for the hormone estradiol. The immunosensor consists of a Au electrode anchored with a Au nanoparticle|thiolated Protein G-scaffold to facilitate immobilisation of an enhanced quantity of an almost uprightly aligned anti-estradiol capture antibody. Competitive immunoassays between an estradiol-bovine saline albumin complex and free estradiol in a sample were then promoted at the immunosensor. Next, SWV and EIS of [Fe(CN)(6)](3-/4-) were sequentially conducted at the immunosensor. SWV yielded familiar peak-shaped voltammograms with the peak currents readily employable in establishing calibration. A dynamic range up to approximately 1200 pg mL(-1) and a detection limit of 18 pg mL(-1) estradiol were achieved. In EIS, an electron transfer resistance estimated from the Nyquist plots was used in the calibration experiments. A comparable dynamic range up to approximately 1000 pg mL(-1) and a detection limit of 26 pg mL(-1) estradiol were obtained. However, a significantly 10 times longer analysis time and substantial effort were required to complete the EIS determinations relative to SWV. Moreover, a large amount of EIS data involving phase angle was collected but ignored because they would not contribute any useful information to quantitative determination. Overall, SWV was determined to be a more rapid, efficient, effective and low cost detection technique than EIS at label-free electrochemical immunosensors.
Reano R, Escobar E Front Bioeng Biotechnol. 2024; 12:1361469.
PMID: 38544977 PMC: 10965549. DOI: 10.3389/fbioe.2024.1361469.
Advances on Hormones and Steroids Determination: A Review of Voltammetric Methods since 2000.
Smajdor J, Paczosa-Bator B, Piech R Membranes (Basel). 2022; 12(12).
PMID: 36557132 PMC: 9782681. DOI: 10.3390/membranes12121225.
A Novel Method for the Detection of SARS-CoV-2 Based on Graphene-Impedimetric Immunosensor.
Zaccariotto G, Silva M, Rocha G, Cesarino I Materials (Basel). 2021; 14(15).
PMID: 34361424 PMC: 8348628. DOI: 10.3390/ma14154230.
Curtis S, Ploense K, Kurnik M, Ortega G, Parolo C, Kippin T Anal Chem. 2019; 91(19):12321-12328.
PMID: 31462040 PMC: 7336365. DOI: 10.1021/acs.analchem.9b02553.
Coelho L, Silva P, Lima V, Pontual E, Paiva P, Napoleao T Evid Based Complement Alternat Med. 2017; 2017:1594074.
PMID: 28367220 PMC: 5359455. DOI: 10.1155/2017/1594074.