Aims: We evaluated the feasibility and image quality of a new scan mode for coronary computed tomography angiography (CTA) with an effective dose of less than 1 mSv.

Methods And Results: In 50 consecutive patients (body weight <or= 100 kg, sinus rhythm <or=60 b.p.m. after pre-medication, coronary CTA was performed using a dual-source CT system with 2 x 128 x 0.6 mm collimation, 0.28 s rotation time, a pitch of 3.2 or 3.4, 100 kV tube voltage and current of 320 mA s. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within one cardiac cycle. Image quality was evaluated using a four-point scale (1 = absence of any artefacts to 4 = uninterpretable). In all 50 patients, imaging was successful. Mean duration of data acquisition was 258 +/- 20 ms. Mean dose-length product was 62 +/- 5 mGy cm, the effective dose was 0.87 +/- 0.07 mSv (0.78-0.99 mSv). Of the 742 coronary artery segments, 94% had an image quality score of 1, 5.0% a score of 2, 0.9% a score of 3, and 4 segments (0.5%) were 'uninterpretable'.

Conclusion: In non-obese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides excellent image quality at a consistent dose below 1.0 mSv.

Citing Articles

Ultra-low-dose coronary computed tomography angiography using photon-counting detector computed tomography.

Araki S, Nakamura S, Takafuji M, Ichikawa Y, Sakuma H, Kitagawa K Eur Heart J Imaging Methods Pract. 2024; 2(3):qyae125.

PMID: 39659699 PMC: 11631184. DOI: 10.1093/ehjimp/qyae125.


[Coronary CT angiography and coronary atherosclerosis : Where do we stand today?].

Achenbach S Herz. 2023; 48(5):352-358.

PMID: 37624391 DOI: 10.1007/s00059-023-05207-0.


High-Pitch Multienergy Coronary CT Angiography in Dual-Source Photon-Counting Detector CT Scanner at Low Iodinated Contrast Dose.

Rajiah P, Dunning C, Rajendran K, Tandon Y, Ahmed Z, Larson N Invest Radiol. 2023; 58(9):681-690.

PMID: 36822655 PMC: 10591289. DOI: 10.1097/RLI.0000000000000961.


Bodyweight-adjusted Contrast Media With Shortened Injection Duration for Step-and-Shoot Coronary Computed Tomography Angiography to Acquire Improved Image Quality.

Jin L, Wang K, Wang X, Li C, Sun Y, Gao P J Thorac Imaging. 2023; 39(3):146-156.

PMID: 36744945 PMC: 11027974. DOI: 10.1097/RTI.0000000000000696.


Intraindividual evaluation of effects of image filter function on image quality in coronary computed tomography angiography.

Jin L, Gao P, Wang K, Li J, Li M Front Cardiovasc Med. 2022; 9:840735.

PMID: 36186969 PMC: 9521173. DOI: 10.3389/fcvm.2022.840735.