Reliability of Measurements of Cervical Spine Range of Motion--comparison of Three Methods

Overview
Journal Phys Ther
Date 1991 Feb 1
PMID 1989013
Citations 89
Authors
Affiliations
Soon will be listed here.
Abstract

To determine reliabilities within and between persons measuring cervical active range of motion (AROM) three methods were examined: use of a cervical-range-of-motion (CROM) instrument, use of a universal goniometer (UG), and visual estimation (VE). Measurements were made on 60 patients with orthopedic disorders of the cervical spine who were divided into three groups of 20 subjects each. All subjects were tested in a standardized seated position using operationally defined goniometric placements and nongoniometric estimation techniques. Cervical flexion and extension, lateral flexion, and rotation were measured. Intraclass correlation coefficients (ICCs) were used to quantify within-tester and between-tester reliability. We found that goniometric measurements of AROM of the cervical spine made by the same physical therapist had ICCs greater than .80 when made with the CROM device or the UG. When different physical therapist measured the same patient's cervical AROM, the CROM device had ICCs greater than .80, whereas the UG and VE generally had ICCs less than .80.

Citing Articles

Development of a Headache Diary and Assessment of Tension-Type Headache Diagnostic Criteria and Oral Behaviors, Joint Range of Motion, and Tenderness to Palpation: An Observational Study.

Gonzalez-Gonzalez A, Herrero A J Chiropr Med. 2025; 23(1-2):37-46.

PMID: 39791002 PMC: 11707374. DOI: 10.1016/j.jcm.2024.02.003.


Cervical and Thoracic Spine Mobility in Rotator Cuff Related Shoulder Pain: A Comparative Analysis with Asymptomatic Controls.

Manoso-Hernando D, Bailon-Cerezo J, Elizagaray-Garcia I, Achutegui-Garcia-Matres P, Suarez-Diez G, Gil-Martinez A J Funct Morphol Kinesiol. 2024; 9(3).

PMID: 39189213 PMC: 11348207. DOI: 10.3390/jfmk9030128.


Comparison of head posture and neck proprioceptive sense of individuals with chronic neck pain and healthy controls: A cross-sectional study.

Yilmaz K, Akkoyun Sert O, Unuvar B, Gercek H J Back Musculoskelet Rehabil. 2024; 37(6):1705-1713.

PMID: 39058438 PMC: 11613015. DOI: 10.3233/BMR-240155.


Predicting functional movement capacity in adults: the effect of range of motion and isometric strength.

Ozkan M, Canli U, Alwhaibi R, Ustaomer K, Karacam A, Orhan B BMC Sports Sci Med Rehabil. 2024; 16(1):145.

PMID: 38956714 PMC: 11221079. DOI: 10.1186/s13102-024-00935-0.


Neck muscle spasticity in patients with disorder of consciousness: a pilot study.

Pingue V, Mirando M, Cazzulani B, Bellaviti G, Saporiti F, Zanga C Eur J Phys Rehabil Med. 2024; 60(3):412-419.

PMID: 38502553 PMC: 11255878. DOI: 10.23736/S1973-9087.24.08176-0.