Effects of Tissue Factor, Thrombomodulin and Elevated Clotting Factor Levels on Thrombin Generation in the Calibrated Automated Thrombogram

Overview
Journal Thromb Haemost
Publisher Thieme
Date 2009 Nov 6
PMID 19888532
Citations 43
Authors
Affiliations
Soon will be listed here.
Abstract

Elevated procoagulant levels have been correlated with increased thrombin generation in vitro and with increased venous thromboembolism (VTE) risk in epidemiological studies. Thrombin generation tests are increasingly being employed as a high throughput method to provide a global measure of procoagulant activity in plasma samples. The objective of this study was to distinguish the effects of assay conditions [tissue factor (TF), thrombomodulin, platelets/lipids] and factor levels on thrombin generation parameters, and determine the conditions and parameters with the highest sensitivity and specificity for detecting elevated factor levels. Thrombin generation was measured using calibrated automated thrombography (CAT) in corn trypsin inhibitor (CTI)-treated platelet-free plasma (PFP) and platelet-rich plasma (PRP). Statistical analysis was performed using logarithms of observed values with analysis of variance that accounted for experiment and treatment. The relative sensitivity of lag time (LT), time to peak (TTP), peak height and endogenous thrombin potential (ETP) to elevated factors XI, IX, VIII, X, and prothrombin was as follows: PFP initiated with 1 pM TF > PFP initiated with 5 pM TF > PRP initiated with 1 pM TF. For all conditions, inclusion of thrombomodulin prolonged the LT and decreased the peak and ETP; however, addition of thrombomodulin did not increase the ability of CAT to detect elevated levels of individual procoagulant factors. In conclusion, CAT conditions differentially affected the sensitivity of thrombin generation to elevated factor levels. Monitoring the peak height and/or ETP following initiation of clotting in PFP with 1 pM TF was most likely to detect hypercoagulability due to increased procoagulant factor levels.

Citing Articles

Effect of plasma levels of factor VIII according to procoagulant phospholipids on the risk of future venous thromboembolism.

Edvardsen M, Hansen E, Ueland T, Latysheva N, Aukrust P, Snir O Res Pract Thromb Haemost. 2025; 9(1):102636.

PMID: 39810988 PMC: 11732527. DOI: 10.1016/j.rpth.2024.102636.


Clot formation and fibrinolysis assays reveal functional differences among hemostatic agents in hemophilia A plasma.

Holle L, Pantazis J, Turecek P, Wolberg A Res Pract Thromb Haemost. 2024; 8(1):102337.

PMID: 38426025 PMC: 10901841. DOI: 10.1016/j.rpth.2024.102337.


Thromboembolic risk with gender-affirming hormone therapy: potential role of global coagulation and fibrinolysis assays.

Bouck E, Grinsztejn E, McNamara M, Stavrou E, Wolberg A Res Pract Thromb Haemost. 2023; 7(6):102197.

PMID: 37822706 PMC: 10562871. DOI: 10.1016/j.rpth.2023.102197.


High plasma levels of C1-inhibitor are associated with lower risk of future venous thromboembolism.

Grover S, Snir O, Hindberg K, Englebert T, Braekkan S, Morelli V J Thromb Haemost. 2023; 21(7):1849-1860.

PMID: 37003465 PMC: 11112258. DOI: 10.1016/j.jtha.2023.03.024.


C1 inhibitor deficiency enhances contact pathway-mediated activation of coagulation and venous thrombosis.

Grover S, Kawano T, Wan J, Tanratana P, Polai Z, Shim Y Blood. 2023; 141(19):2390-2401.

PMID: 36701760 PMC: 10273165. DOI: 10.1182/blood.2022018849.


References
1.
Gerotziafas G, Depasse F, Busson J, Leflem L, Elalamy I, Samama M . Towards a standardization of thrombin generation assessment: the influence of tissue factor, platelets and phospholipids concentration on the normal values of Thrombogram-Thrombinoscope assay. Thromb J. 2005; 3:16. PMC: 1291409. DOI: 10.1186/1477-9560-3-16. View

2.
Keularts I, Zivelin A, Seligsohn U, Hemker H, Beguin S . The role of factor XI in thrombin generation induced by low concentrations of tissue factor. Thromb Haemost. 2001; 85(6):1060-5. View

3.
Meijers J, Tekelenburg W, Bouma B, Bertina R, Rosendaal F . High levels of coagulation factor XI as a risk factor for venous thrombosis. N Engl J Med. 2000; 342(10):696-701. DOI: 10.1056/NEJM200003093421004. View

4.
Dargaud Y, Luddington R, Gray E, Negrier C, Lecompte T, Petros S . Effect of standardization and normalization on imprecision of calibrated automated thrombography: an international multicentre study. Br J Haematol. 2007; 139(2):303-9. DOI: 10.1111/j.1365-2141.2007.06785.x. View

5.
Hemker H, Giesen P, Al Dieri R, Regnault V, de Smedt E, Wagenvoord R . Calibrated automated thrombin generation measurement in clotting plasma. Pathophysiol Haemost Thromb. 2003; 33(1):4-15. DOI: 10.1159/000071636. View