» Articles » PMID: 19856256

Real-time Elastography and Contrast-enhanced Ultrasound for the Assessment of Thyroid Nodules

Overview
Specialty Endocrinology
Date 2009 Oct 27
PMID 19856256
Citations 42
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Work-up of thyroid nodules remains challenging. Recent technologies enable determination of tissue elasticity and perfusion using ultrasound devices. The aim of the present study was to evaluate real-time elastography (RTE) and contrast-enhanced ultrasound with Sonovue (CEUS) for the differentiation of benign and malignant thyroid nodules.

Materials And Methods: Inclusion criteria were: nodules ≥1 cm, non-functioning or hypo-functioning on radionuclide scanning, and cytological/histological assessment. All patients received conventional ultrasound, RTE and CEUS. RTE was classified as: Elasticity-Score (ES)1 = soft, ES2 = predominantly soft, ES3 = predominantly hard, ES4 = hard nodule. CEUS-video clips were digitally recorded and analyzed using time-intensity-curves within selected regions-of-interest.

Results: Fifty-three nodules in 50 patients were available for analysis. Forty-six nodules were benign on cytology/histology, 6 nodules were papillary carcinoma and one nodule was a follicular carcinoma. Nodule margin irregularity was the ultrasound pattern most predictive of malignancy with sensitivity 57% (95% confidence interval: 18-90%) and specificity 85% (71-94% p<0.05). When using ES3&4 for the diagnosis of malignant nodules sensitivity and specificity were 86% (42-99.7%) and 87% (75-95%), respectively (p = 0.0003). The only malignant nodule missed with RTE was a follicular carcinoma. Sensitivity for the diagnosis of papillary carcinoma therefore was 100%. No specific CEUS pattern could be identified to differentiate between benign and malignant nodules.

Conclusions: RTE seems to be a useful tool in the work-up of thyroid nodules to exclude papillary thyroid cancer. However, follicular carcinoma remains a challenging problem. CEUS did not improve the characterization of thyroid nodules in this preliminary study.

Citing Articles

Thyroid ultrasound and its ancillary techniques.

Bojunga J, Trimboli P Rev Endocr Metab Disord. 2023; 25(1):161-173.

PMID: 37946091 DOI: 10.1007/s11154-023-09841-1.


The predictive models based on multimodality ultrasonography for the differential diagnosis of thyroid nodules smaller than 10 mm.

Li G, Ma S, Zhang F, Jia C, Liu L, Gao F Br J Radiol. 2023; 96(1149):20221120.

PMID: 37427752 PMC: 10461269. DOI: 10.1259/bjr.20221120.


Clinical Application of C-TIRADS Category and Contrast-Enhanced Ultrasound in Differential Diagnosis of Solid Thyroid Nodules Measuring ≥1 cm.

Jin Z, Zhu Y, Lei Y, Yu X, Jiang N, Gao Y Med Sci Monit. 2022; 28:e936368.

PMID: 35668611 PMC: 9188288. DOI: 10.12659/MSM.936368.


The Role of CEUS in the Evaluation of Thyroid Cancer: From Diagnosis to Local Staging.

Sorrenti S, Dolcetti V, Fresilli D, Del Gaudio G, Pacini P, Huang P J Clin Med. 2021; 10(19).

PMID: 34640574 PMC: 8509399. DOI: 10.3390/jcm10194559.


Multimode ultrasonic technique is recommended for the differential diagnosis of thyroid cancer.

Wang J, He X, Ma L, Li M, Sun L, Jiang J PeerJ. 2020; 8:e9112.

PMID: 32411540 PMC: 7204870. DOI: 10.7717/peerj.9112.