» Articles » PMID: 19833812

Low-frequency Assessment of Airway and Tissue Mechanics in Ventilated COPD Patients

Overview
Date 2009 Oct 17
PMID 19833812
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Low-frequency forced oscillations have increasingly been employed to characterize airway and tissue mechanics separately in the normal respiratory system and animal models of lung disease; however, few data are available on the use of this method in chronic obstructive pulmonary disease (COPD). We studied 30 intubated and mechanically ventilated patients (COPD, n = 9; acute exacerbation of COPD, n = 21) during short apneic intervals at different levels of positive end-expiratory pressure (PEEP), with small-amplitude forced oscillations between 0.4 and 4.8 Hz. In 16 patients, measurements were made before and after inhalation of fenoterol hydrobromide plus ipratropium bromide (Berodual). Newtonian resistance and coefficients of tissue resistance (G) and elastance (H) were estimated from the respiratory system impedance (Zrs) data by model fitting. Apart from some extremely high Zrs data obtained primarily at relatively low PEEP levels, the model yielded a reasonable partitioning of the airway and tissue parameters, and the inclusion of further parameters did not improve the model performance. With increasing PEEP, Newtonian resistance and the ratio G/H decreased, reflecting the volume dependence of the airway caliber and the improved homogeneity of the lungs, respectively. Bronchodilation after the administration of Berodual was also associated with simultaneous decreases in G and H, indicating recruitment of lung units. In conclusion, the measurement of low-frequency Zrs can be accomplished in ventilated COPD patients during short apneic periods and offers valuable information on the mechanical status of the airways and tissues.

Citing Articles

Clinical significance and applications of oscillometry.

Kaminsky D, Simpson S, Berger K, Calverley P, de Melo P, Dandurand R Eur Respir Rev. 2022; 31(163).

PMID: 35140105 PMC: 9488764. DOI: 10.1183/16000617.0208-2021.


A comparison of endotracheal tube compensation techniques for the measurement of respiratory mechanical impedance at low frequencies.

Cruz A, Herrmann J, Carvalho C, Kaczka D J Clin Monit Comput. 2021; 36(5):1461-1477.

PMID: 34910285 PMC: 9198108. DOI: 10.1007/s10877-021-00788-9.


Low Frequency Forced Oscillation Lung Function Test Can Distinguish Dynamic Tissue Non-linearity in COPD Patients.

Ghita M, Copot D, Ghita M, Derom E, Ionescu C Front Physiol. 2019; 10:1390.

PMID: 31803060 PMC: 6877497. DOI: 10.3389/fphys.2019.01390.


An Official American Thoracic Society/European Respiratory Society Workshop Report: Evaluation of Respiratory Mechanics and Function in the Pediatric and Neonatal Intensive Care Units.

Peterson-Carmichael S, Seddon P, Cheifetz I, Frerichs I, Hall G, Hammer J Ann Am Thorac Soc. 2016; 13(2):S1-11.

PMID: 26848609 PMC: 5461957. DOI: 10.1513/AnnalsATS.201511-730ST.


Effects of respiratory mechanics on the capnogram phases: importance of dynamic compliance of the respiratory system.

Babik B, Csorba Z, Czovek D, Mayr P, Bogats G, Petak F Crit Care. 2012; 16(5):R177.

PMID: 23031408 PMC: 3682277. DOI: 10.1186/cc11659.