» Articles » PMID: 19747211

Ultrasound Measures of Muscle Thickness: Intra-examiner Reliability and Influence of Body Position

Overview
Date 2009 Sep 15
PMID 19747211
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

Ultrasound is an inexpensive and practical alternative to gold standard measures of muscle mass. Changes in body position may lead to intra-muscular fluid shifts that may affect the reliability of ultrasound measures. We assessed test-retest reliability of ultrasound measures of muscle thickness and the effect of position on these measures. Measures of muscle thickness were made from B-mode ultrasound images in 18 healthy participants. Repeated measurements were made by one examiner from two participant positions; standing and recumbent, from 18 anatomical sites. Results demonstrated high test-retest reliability for measures taken in both participant positions [intra-class coefficient (ICC) scores 0.65 to 0.94], except for the recumbent posterior lower leg measures (ICC 0.34). Recumbent measures were significantly smaller than those taken with participants standing. Length of time participants spent lying down did not significantly affect measures, indicating that any changes in intra-muscular fluid related to the time spent recumbent are negligible.

Citing Articles

Methodologies and clinical applications of lower limb muscle ultrasound in critically ill patients: a systematic review and meta-analysis.

Venco R, Artale A, Formenti P, Deana C, Mistraletti G, Umbrello M Ann Intensive Care. 2024; 14(1):163.

PMID: 39443352 PMC: 11499498. DOI: 10.1186/s13613-024-01395-y.


The concurrent validity of a portable ultrasound probe for muscle thickness measurements.

Homer K, Cross M, Jukic I Clin Physiol Funct Imaging. 2024; 45(1):e12901.

PMID: 39237476 PMC: 11650541. DOI: 10.1111/cpf.12901.


Ultrasound assessment of degenerative muscle sarcopenia: the University of Barcelona ultrasound scoring system for sarcopenia.

Moller Parera I, Miguel M, Blasi J, Piccaso R, Hammer H, Ortiz-Sagrista J RMD Open. 2023; 9(1).

PMID: 36707106 PMC: 9884912. DOI: 10.1136/rmdopen-2022-002779.


Inter and intra-examiner reliability of musculoskeletal ultrasound scanning of Anterior Talofibular Ligament and ankle muscles.

Ozgul B, Starbuck C, Polat M, Abdeen R, Nester C J Ultrasound. 2022; 26(1):137-146.

PMID: 36048331 PMC: 10063751. DOI: 10.1007/s40477-022-00699-8.


Protocol and reference values for minimal detectable change of MyotonPRO and ultrasound imaging measurements of muscle and subcutaneous tissue.

Muckelt P, Warner M, Cheliotis-James T, Muckelt R, Hastermann M, Schoenrock B Sci Rep. 2022; 12(1):13654.