» Articles » PMID: 19739089

Flow Cytometry APC-tandem Dyes Are Degraded Through a Cell-dependent Mechanism

Overview
Journal Cytometry A
Specialties Cell Biology
Radiology
Date 2009 Sep 10
PMID 19739089
Citations 13
Authors
Affiliations
Soon will be listed here.
Abstract

Technological developments of multiparametric flow cytometry come along with the generation of new dyes. The APC-tandem dyes, which combine the fluorophores APC and Cy7/H7, allow the detection of a specific signal in the APC-Cy7/H7 channel along with an unexpected nonspecific signal in the APC channel. Depending on the magnitude of the latter, it may be a handicap for interpreting the data of multicolor labeling experiments. We investigated the alteration of the APC-tandem dyes by labeling peripheral blood cells with antibodies directed toward leukocyte surface proteins and by analyzing cells by flow cytometry. Our results show that the APC-Cy7/H7 tandem fluorochromes degraded over time. Nonspecific APC signal was observed with the various antibodies tested only upon cell attachment but not under bead linkage. Moreover, the percentage of degradation of the APC-Cy7/H7 dyes was dependent on the cell type analyzed. Interestingly, nonspecific APC signal strongly decreased when the metabolic activity of immunolabeled cells was inhibited or when cells were incubated with vitamin C. This study demonstrates that the APC-tandem dyes are the target of cell-dependent degradation, which may be antagonized. These findings will allow cytometer users to optimize their multicolor panels.

Citing Articles

T Cells Specific for a Mycobacterial Glycolipid Expand after Intravenous Bacillus Calmette-Guérin Vaccination.

Layton E, Barman S, Wilburn D, Yu K, Smith M, Altman J J Immunol. 2021; 206(6):1240-1250.

PMID: 33536255 PMC: 7939042. DOI: 10.4049/jimmunol.2001065.


FACS protocol for direct comparison of cell populations isolated from mice.

Ludwik K, Sandusky Z, Wright E, Lannigan D STAR Protoc. 2021; 2(1):100270.

PMID: 33490986 PMC: 7811174. DOI: 10.1016/j.xpro.2020.100270.


T cell and antibody functional correlates of severe COVID-19.

Yu K, Fischinger S, Smith M, Atyeo C, Cizmeci D, Wolf C medRxiv. 2020; .

PMID: 33269369 PMC: 7709190. DOI: 10.1101/2020.11.25.20235150.


Worry and FRET: ROS Production Leads to Fluorochrome Tandem Degradation and impairs Interpretation of Flow Cytometric Results.

Jensen I, McGonagill P, Lefebvre M, Griffith T, Harty J, Badovinac V Immunity. 2020; 52(3):419-421.

PMID: 32187510 PMC: 7251922. DOI: 10.1016/j.immuni.2020.02.003.


Methodological considerations for the high sensitivity detection of multiple myeloma measurable residual disease.

Soh K, Tario Jr J, Hahn T, Hillengass J, McCarthy P, Wallace P Cytometry B Clin Cytom. 2019; 98(2):161-173.

PMID: 31868315 PMC: 7741435. DOI: 10.1002/cyto.b.21862.