» Articles » PMID: 19719745

Confidence in Altman-Bland Plots: a Critical Review of the Method of Differences

Overview
Specialties Pharmacology
Physiology
Date 2009 Sep 2
PMID 19719745
Citations 109
Authors
Affiliations
Soon will be listed here.
Abstract

1. Altman and Bland argue that the virtue of plotting differences against averages in method-comparison studies is that 95% confidence limits for the differences can be constructed. These allow authors and readers to judge whether one method of measurement could be substituted for another. 2. The technique is often misused. So I have set out, by statistical argument and worked examples, to advise pharmacologists and physiologists how best to construct these limits. 3. First, construct a scattergram of differences on averages, then calculate the line of best fit for the linear regression of differences on averages. If the slope of the regression is shown to differ from zero, there is proportional bias. 4. If there is no proportional bias and if the scatter of differences is uniform (homoscedasticity), construct 'classical' 95% confidence limits. 5. If there is proportional bias yet homoscedasticity, construct hyperbolic 95% confidence limits (prediction interval) around the line of best fit. 6. If there is proportional bias and the scatter of values for differences increases progressively as the average values increase (heteroscedasticity), log-transform the raw values from the two methods and replot differences against averages. If this eliminates proportional bias and heteroscedasticity, construct 'classical' 95% confidence limits. Otherwise, construct horizontal V-shaped 95% confidence limits around the line of best fit of differences on averages or around the weighted least products line of best fit to the original data. 7. In designing a method-comparison study, consult a qualified biostatistician, obey the rules of randomization and make replicate observations.

Citing Articles

Calcaneal Ultrasound Attenuation: Does the Region of Interest and Loading Influence the Repeatability of Measurement?.

Robertson A, Jones B, Langton C, Wearing S Calcif Tissue Int. 2025; 116(1):48.

PMID: 40063094 PMC: 11893676. DOI: 10.1007/s00223-025-01357-x.


Correlation properties and respiratory frequency of ECG-derived heart rate variability during multiple race-pace running intervals in female and male long-distance runners.

Gronwald T, Schaffarczyk M, Fohrmann D, Hoos O, Hollander K Physiol Rep. 2025; 13(3):e70177.

PMID: 39903559 PMC: 11792992. DOI: 10.14814/phy2.70177.


Analysis of the Reliability of Feather Sections for Corticosterone Measurement in Pekin Ducks.

Lim S, Kim C, Yang K, Lee W, Kim S, Choi Y Animals (Basel). 2025; 15(2).

PMID: 39858140 PMC: 11758332. DOI: 10.3390/ani15020138.


Assessment of the impact of different SARS-CoV-2 inactivation operations on colistin sulfate plasma concentration results.

Ma Y, Yang X, Gu J BMC Infect Dis. 2025; 25(1):12.

PMID: 39754058 PMC: 11697833. DOI: 10.1186/s12879-024-10353-9.


Automated Assessment of Pelvic Longitudinal Rotation Using Computer Vision in Canine Hip Dysplasia Screening.

Franco-Goncalo P, Leite P, Alves-Pimenta S, Colaco B, Goncalves L, Filipe V Vet Sci. 2024; 11(12).

PMID: 39728970 PMC: 11680104. DOI: 10.3390/vetsci11120630.