» Articles » PMID: 19663953

A Systematic Review on the Accuracy and the Clinical Outcome of Computer-guided Template-based Implant Dentistry

Overview
Specialty Dentistry
Date 2009 Aug 12
PMID 19663953
Citations 87
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: The aim of this systematic review was to analyze the dental literature regarding accuracy and clinical application in computer-guided template-based implant dentistry.

Materials And Methods: An electronic literature search complemented by manual searching was performed to gather data on accuracy and surgical, biological and prosthetic complications in connection with computer-guided implant treatment. For the assessment of accuracy meta-regression analysis was performed. Complication rates are descriptively summarized.

Results: From 3120 titles after the literature search, eight articles met the inclusion criteria regarding accuracy and 10 regarding the clinical performance. Meta-regression analysis revealed a mean deviation at the entry point of 1.07 mm (95% CI: 0.76-1.22 mm) and at the apex of 1.63 mm (95% CI: 1.26-2 mm). No significant differences between the studies were found regarding method of template production or template support and stabilization. Early surgical complications occurred in 9.1%, early prosthetic complications in 18.8% and late prosthetic complications in 12% of the cases. Implant survival rates of 91-100% after an observation time of 12-60 months are reported in six clinical studies with 537 implants mainly restored immediately after flapless implantation procedures.

Conclusion: Computer-guided template-based implant placement showed high implant survival rates ranging from 91% to 100%. However, a considerable number of technique-related perioperative complications were observed. Preclinical and clinical studies indicated a reasonable mean accuracy with relatively high maximum deviations. Future research should be directed to increase the number of clinical studies with longer observation periods and to improve the systems in terms of perioperative handling, accuracy and prosthetic complications.

Citing Articles

Efficacy of Novel Digital-Based Surgical Guide in the Limited Interocclusal Distance.

Park W, Kim K, Cho S, Lee S Bioengineering (Basel). 2025; 11(12.

PMID: 39767995 PMC: 11674003. DOI: 10.3390/bioengineering11121177.


Accuracy of robot-assisted implant surgery versus freehand placement: a retrospective clinical study.

Younis H, Xu B, Acharya K, He L, Du L, Elayah S Int J Implant Dent. 2025; 11(1):1.

PMID: 39751717 PMC: 11699033. DOI: 10.1186/s40729-024-00586-3.


Influence of Bone Conditions on the Accuracy of Implant Placement.

Gong Z, Shen Y, Qi S, Cao L, Fan X, Lu C Bioengineering (Basel). 2024; 11(11).

PMID: 39593821 PMC: 11591606. DOI: 10.3390/bioengineering11111161.


Accuracy of full-guided versus half-guided implant procedures carried out with digital implant planning software by students as part of a university curriculum.

Einsiedel D, Giacaman S, Seidel A, Berger L, Buchbender M, Wichmann M BMC Med Educ. 2024; 24(1):1316.

PMID: 39548519 PMC: 11566595. DOI: 10.1186/s12909-024-06280-7.


Comparative evaluation of accuracy of implants placed with thermoplastic and three-dimensional-printed surgical guides: A randomized controlled trial.

Husain F, Grover V, Bhaskar N, Jain A J Indian Soc Periodontol. 2024; 28(2):244-251.

PMID: 39411727 PMC: 11472977. DOI: 10.4103/jisp.jisp_256_23.