» Articles » PMID: 19641907

Rapid Screening of Active Ingredients in Drugs by Mass Spectrometry with Low-temperature Plasma Probe

Overview
Specialty Chemistry
Date 2009 Jul 31
PMID 19641907
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

A high-throughput method for rapid screening of active ingredients in drugs has been developed with mass spectrometry coupled to a low-temperature plasma (LTP) probe ion source. Without sample preparation or pretreatment, the active ingredients of 11 types of commercial pharmaceuticals, including hormones, antipyretic analgesics, cardiovascular, digestant, neuro-psychotherapeutic, diuretic, antithyroid, sulfa anti-inflammatory, antiparastic, sedative-hypnotics, and antibacterial, were directly desorbed/ionized and detected by a linear ion trap mass spectrometry (MS). The structures of these ingredients were elucidated by tandem MS. The analysis of 18 methyltestosterone tablets could be accomplished within 1.9 min, which allows fast detection with a speed of approximate 600 samples within 1 h. This work demonstrated that LTP probe ion source combined with MS is a high-throughput method for screening of pharmaceuticals and potentially applied to on-line quality control in pharmaceutical industry.

Citing Articles

Screening of volatile organic compounds (VOCs) from liquid fungal cultures using ambient mass spectrometry.

Heffernan D, Pilz M, Klein M, Haack M, Race A, Bruck T Anal Bioanal Chem. 2023; 415(18):4615-4627.

PMID: 37389599 PMC: 10329071. DOI: 10.1007/s00216-023-04769-6.


Applications and challenges of low temperature plasma in pharmaceutical field.

Gao L, Shi X, Wu X J Pharm Anal. 2021; 11(1):28-36.

PMID: 33717609 PMC: 7930796. DOI: 10.1016/j.jpha.2020.05.001.


Remote Atmospheric Pressure Infrared Matrix-Assisted Laser Desorption-Ionization Mass Spectrometry (Remote IR-MALDI MS) of Proteins.

Fatou B, Ziskind M, Saudemont P, Quanico J, Focsa C, Salzet M Mol Cell Proteomics. 2018; 17(8):1637-1649.

PMID: 29653959 PMC: 6072536. DOI: 10.1074/mcp.TIR117.000582.


Desorption Flame-Induced Atmospheric Pressure Chemical Ionization Mass Spectrometry for Rapid Real-World Sample Analysis.

Cheng S, Chen S, Shiea J Mass Spectrom (Tokyo). 2017; 6(Spec Iss):S0065.

PMID: 28573084 PMC: 5448330. DOI: 10.5702/massspectrometry.S0065.


An Integrated Microfabricated Chip with Double Functions as an Ion Source and Air Pump Based on LIGA Technology.

Li H, Jiang L, Guo C, Zhu J, Jiang Y, Chen Z Sensors (Basel). 2017; 17(1).

PMID: 28054980 PMC: 5298660. DOI: 10.3390/s17010087.