» Articles » PMID: 19598054

Performance of an N95 Filtering Facepiece Particulate Respirator and a Surgical Mask During Human Breathing: Two Pathways for Particle Penetration

Overview
Publisher Informa Healthcare
Date 2009 Jul 15
PMID 19598054
Citations 122
Authors
Affiliations
Soon will be listed here.
Abstract

The protection level offered by filtering facepiece particulate respirators and face masks is defined by the percentage of ambient particles penetrating inside the protection device. There are two penetration pathways: (1) through the faceseal leakage, and the (2) filter medium. This study aimed at differentiating the contributions of these two pathways for particles in the size range of 0.03-1 microm under actual breathing conditions. One N95 filtering facepiece respirator and one surgical mask commonly used in health care environments were tested on 25 subjects (matching the latest National Institute for Occupational Safety and Health fit testing panel) as the subjects performed conventional fit test exercises. The respirator and the mask were also tested with breathing manikins that precisely mimicked the prerecorded breathing patterns of the tested subjects. The penetration data obtained in the human subject- and manikin-based tests were compared for different particle sizes and breathing patterns. Overall, 5250 particle size- and exercise-specific penetration values were determined. For each value, the faceseal leakage-to-filter ratio was calculated to quantify the relative contributions of the two penetration pathways. The number of particles penetrating through the faceseal leakage of the tested respirator/mask far exceeded the number of those penetrating through the filter medium. For the N95 respirator, the excess was (on average) by an order of magnitude and significantly increased with an increase in particle size (p < 0.001): approximately 7-fold greater for 0.04 microm, approximately 10-fold for 0.1 microm, and approximately 20-fold for 1 microm. For the surgical mask, the faceseal leakage-to-filter ratio ranged from 4.8 to 5.8 and was not significantly affected by the particle size for the tested submicrometer fraction. Facial/body movement had a pronounced effect on the relative contribution of the two penetration pathways. Breathing intensity and facial dimensions showed some (although limited) influence. Because most of the penetrated particles entered through the faceseal, the priority in respirator/mask development should be shifted from improving the efficiency of the filter medium to establishing a better fit that would eliminate or minimize faceseal leakage.

Citing Articles

Perceived Effectiveness and Sustainability of Face Masks Among German Citizens During the 2nd Wave of the COVID-19 Pandemic-A Cross-Sectional Study.

Fendt M, Leal Filho W, Barbir J, Boenecke J Front Public Health. 2025; 10:768454.

PMID: 39949531 PMC: 11823475. DOI: 10.3389/fpubh.2022.768454.


Next-Generation Custom-Fit Reusable Respiratory Protective Device with Continuous Fit Monitoring - Part I: Custom-Fit Design.

Park S, Tian Y, Bergman M, Pollard J, Zhuang Z, Jayaraman S J Int Soc Respir Prot. 2025; 41(1):22-37.

PMID: 39781283 PMC: 11708506.


Interactive Simulation of Nonpharmaceutical Interventions of Airborne Disease Transmission in Office Settings.

Zimmerman T, Sharma N, Bulu H, Burrowes V, Beymer D, Mukherjee V Int J Environ Res Public Health. 2024; 21(11).

PMID: 39595680 PMC: 11593966. DOI: 10.3390/ijerph21111413.


Knowledge, Attitude, and Practice of Mask Usage Among Patients in a Tertiary Dental Care Center.

George J, Kayyalakkal M, Koppara F, Christalin R, Shaji D, Narayanankutty S J Pharm Bioallied Sci. 2024; 16(Suppl 3):S2244-S2246.

PMID: 39346337 PMC: 11426755. DOI: 10.4103/jpbs.jpbs_187_24.


Efficacy and feasibility of a novel semi-facial respirator with chitosan nanoparticles on the incidence of SARS-CoV-2 infection in healthcare professionals: randomized controlled trial.

Kubota A, Rosa M, Baraldi S, Vale J, da Silva J, Carneiro M BMC Infect Dis. 2024; 24(1):1061.

PMID: 39333902 PMC: 11429083. DOI: 10.1186/s12879-024-09966-x.


References
1.
MYERS W, Allender J, Plummer R, Stobbe T . Parameters that bias the measurement of airborne concentration within a respirator. Am Ind Hyg Assoc J. 1986; 47(2):106-14. DOI: 10.1080/15298668691389423. View

2.
Chen C, Willeke K . Characteristics of face seal leakage in filtering facepieces. Am Ind Hyg Assoc J. 1992; 53(9):533-9. DOI: 10.1080/15298669291360120. View

3.
Stafford R, ETTINGER H, Rowland T . Respirator cartridge filter efficiency under cyclic-and steady-flow conditions. Am Ind Hyg Assoc J. 1973; 34(5):182-92. DOI: 10.1080/0002889738506832. View

4.
MYERS W, Allender J, Iskander W, Stanley C . Causes of in-facepiece sampling bias--I. Half-facepiece respirators. Ann Occup Hyg. 1988; 32(3):345-59. DOI: 10.1093/annhyg/32.3.345. View

5.
Crutchfield C, Fairbank E, Greenstein S . Effect of test exercises and mask donning on measured respirator fit. Appl Occup Environ Hyg. 2000; 14(12):827-37. DOI: 10.1080/104732299302062. View