» Articles » PMID: 19574238

Comparison of Long-term Surgical Success of Ahmed Valve Implant Versus Trabeculectomy in Open-angle Glaucoma

Overview
Journal Br J Ophthalmol
Specialty Ophthalmology
Date 2009 Jul 4
PMID 19574238
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

Aim: To compare the long-term intraocular pressure (IOP) outcomes of Ahmed Glaucoma Valve (AGV) implantation to trabeculectomy with mitomycin C (MMC) in open-angle glaucoma (OAG).

Methods: 78 OAG patients who underwent AGV implantation were matched with respect to age, preoperative surgery, preoperative IOP and preoperative medicines to 88 OAG patients who underwent trabeculectomy with MMC with a minimum of 3 years' follow-up. The cumulative probability of success between the two groups with different criteria was analysed: (1) an IOP < or =21 mm Hg and a reduction of IOP>/=15% from baseline; and (2) an IOP < or =18 mm Hg and a reduction of IOP > or =20% from baseline. No loss of light perception, no additional glaucoma surgery and no hypotony were also required.

Results: The 5-year cumulative probability of success was not statistically significant between eyes that had an AGV or trabeculectomy with MMC when success was defined as criteria A (p = 0.094). However, when success was defined according to criteria B, eyes undergoing trabeculectomy with MMC had a higher rate of success (p = 0.024).

Conclusions: Trabeculectomy with MMC has a significantly higher 5-year cumulative probability of success compared with AGV implants when greater reduction IOP is necessary.

Citing Articles

Limbal reconstruction in uveitic glaucoma patient with exposed Ahmed valve coincident with corneal melting and iris prolapse using multiple corneoscleral allografts.

Kandarakis S, Doumazos L, Timpilis M, Karageorgiou G, Petrou P, Georgalas I Rom J Ophthalmol. 2024; 68(1):60-64.

PMID: 38617728 PMC: 11007568. DOI: 10.22336/rjo.2024.12.


Ahmed Glaucoma Valve Implantation to Reduce Intraocular Pressure: Updated Perspectives.

Arikan G, Gunenc U Clin Ophthalmol. 2023; 17:1833-1845.

PMID: 37405008 PMC: 10317551. DOI: 10.2147/OPTH.S342721.


Comparison of tube shunt implantation and trabeculectomy for glaucoma: a systematic review and meta-analysis.

Luo N, Liu M, Hao M, Xu R, Wang F, Zhang W BMJ Open. 2023; 13(4):e065921.

PMID: 37080625 PMC: 10273552. DOI: 10.1136/bmjopen-2022-065921.


Long-term outcome of supraciliary gold micro shunt in refractory glaucoma.

Figus M, Loiudice P, Passani A, Perciballi L, Agnifili L, Nardi M Acta Ophthalmol. 2021; 100(3):e753-e759.

PMID: 34318992 PMC: 9291161. DOI: 10.1111/aos.14989.


The role of primary needle revision after Ahmed glaucoma valve (AGV) implantation.

Yadgari M, Hassanpour K, Vafaei F Int Ophthalmol. 2020; 41(1):99-105.