Comparison of Long-term Surgical Success of Ahmed Valve Implant Versus Trabeculectomy in Open-angle Glaucoma
Overview
Affiliations
Aim: To compare the long-term intraocular pressure (IOP) outcomes of Ahmed Glaucoma Valve (AGV) implantation to trabeculectomy with mitomycin C (MMC) in open-angle glaucoma (OAG).
Methods: 78 OAG patients who underwent AGV implantation were matched with respect to age, preoperative surgery, preoperative IOP and preoperative medicines to 88 OAG patients who underwent trabeculectomy with MMC with a minimum of 3 years' follow-up. The cumulative probability of success between the two groups with different criteria was analysed: (1) an IOP < or =21 mm Hg and a reduction of IOP>/=15% from baseline; and (2) an IOP < or =18 mm Hg and a reduction of IOP > or =20% from baseline. No loss of light perception, no additional glaucoma surgery and no hypotony were also required.
Results: The 5-year cumulative probability of success was not statistically significant between eyes that had an AGV or trabeculectomy with MMC when success was defined as criteria A (p = 0.094). However, when success was defined according to criteria B, eyes undergoing trabeculectomy with MMC had a higher rate of success (p = 0.024).
Conclusions: Trabeculectomy with MMC has a significantly higher 5-year cumulative probability of success compared with AGV implants when greater reduction IOP is necessary.
Kandarakis S, Doumazos L, Timpilis M, Karageorgiou G, Petrou P, Georgalas I Rom J Ophthalmol. 2024; 68(1):60-64.
PMID: 38617728 PMC: 11007568. DOI: 10.22336/rjo.2024.12.
Ahmed Glaucoma Valve Implantation to Reduce Intraocular Pressure: Updated Perspectives.
Arikan G, Gunenc U Clin Ophthalmol. 2023; 17:1833-1845.
PMID: 37405008 PMC: 10317551. DOI: 10.2147/OPTH.S342721.
Luo N, Liu M, Hao M, Xu R, Wang F, Zhang W BMJ Open. 2023; 13(4):e065921.
PMID: 37080625 PMC: 10273552. DOI: 10.1136/bmjopen-2022-065921.
Long-term outcome of supraciliary gold micro shunt in refractory glaucoma.
Figus M, Loiudice P, Passani A, Perciballi L, Agnifili L, Nardi M Acta Ophthalmol. 2021; 100(3):e753-e759.
PMID: 34318992 PMC: 9291161. DOI: 10.1111/aos.14989.
The role of primary needle revision after Ahmed glaucoma valve (AGV) implantation.
Yadgari M, Hassanpour K, Vafaei F Int Ophthalmol. 2020; 41(1):99-105.
PMID: 32851559 DOI: 10.1007/s10792-020-01556-5.