The Use of a Single Inertial Sensor to Identify Stride, Step, and Stance Durations of Running Gait

Overview
Journal J Sci Med Sport
Specialty Orthopedics
Date 2009 Jul 4
PMID 19574098
Citations 27
Authors
Affiliations
Soon will be listed here.
Abstract

Current developments in inertial sensor technology could enable the measurement of running gait outside of the traditional laboratory environment. The purpose of this research was to determine the level of agreement between an inertial sensor and infrared camera based estimates of stride, step, and stance durations across a range of running speeds. An inertial sensor was placed on the sacrum of 10 elite national standard runners, and the stride, step, and stance of running gait were compared. A total of 504 samples were collected and the running velocities stratified into three equal groups of low (10-12 km/h), medium (13-15 km/h), and high (16-19 km/h). A single inertial sensor was found to be suitable for identifying stride duration with Bland-Altman limits of agreement of 95%. The stride data showed agreement at less than 0.02s for most limits. Agreement for step showed five of the eight upper and lower limits below 0.02s. The largest differences between both capture methods were for stance. An average bias of 0.0008s was found and standard error ranged between 0.0004s and 0.0009s across all variables. The results from this research found that inertial sensors are suitable to measure stride, step, and stance duration, and provide the opportunity to measure running gait outside of the traditional laboratory.

Citing Articles

Identifying right and left impact using the derivative of linear resultant acceleration from a single sacrum-mounted IMU.

Chebbi A, Robinson R, Donahue S, Hahn M Wearable Technol. 2025; 6:e14.

PMID: 40071240 PMC: 11894424. DOI: 10.1017/wtc.2025.4.


Automated Detection of Change of Direction in Basketball Players Using Xsens Motion Tracking.

Pinelli S, Zinno R, Jodar-Portas A, Prats-Puig A, Font-Llado R, Bragonzoni L Sensors (Basel). 2025; 25(3).

PMID: 39943581 PMC: 11820490. DOI: 10.3390/s25030942.


Evaluation of WIMU Sensor Performance in Estimating Running Stride and Vertical Stiffness in Football Training Sessions: A Comparison with Smart Insoles.

Pinelli S, Mandorino M, Lacome M, Fantozzi S Sensors (Basel). 2025; 24(24.

PMID: 39771821 PMC: 11679392. DOI: 10.3390/s24248087.


Post-Stroke Functional Changes: In-Depth Analysis of Clinical Tests and Motor-Cognitive Dual-Tasking Using Wearable Sensors.

Abdollahi M, Rashedi E, Kuber P, Jahangiri S, Kazempour B, Dombovy M Bioengineering (Basel). 2024; 11(4).

PMID: 38671771 PMC: 11048064. DOI: 10.3390/bioengineering11040349.


Gait Event Detection and Travel Distance Using Waist-Worn Accelerometers across a Range of Speeds: Automated Approach.

Ramli A, Liu X, Berndt K, Chuah C, Goude E, Kaethler L Sensors (Basel). 2024; 24(4).

PMID: 38400313 PMC: 10891633. DOI: 10.3390/s24041155.