» Articles » PMID: 19535480

Single-unit Stability Using Chronically Implanted Multielectrode Arrays

Overview
Journal J Neurophysiol
Specialties Neurology
Physiology
Date 2009 Jun 19
PMID 19535480
Citations 116
Authors
Affiliations
Soon will be listed here.
Abstract

The use of chronic intracortical multielectrode arrays has become increasingly prevalent in neurophysiological experiments. However, it is not obvious whether neuronal signals obtained over multiple recording sessions come from the same or different neurons. Here, we develop a criterion to assess single-unit stability by measuring the similarity of 1) average spike waveforms and 2) interspike interval histograms (ISIHs). Neuronal activity was recorded from four Utah arrays implanted in primary motor and premotor cortices in three rhesus macaque monkeys during 10 recording sessions over a 15- to 17-day period. A unit was defined as stable through a given day if the stability criterion was satisfied on all recordings leading up to that day. We found that 57% of the original units were stable through 7 days, 43% were stable through 10 days, and 39% were stable through 15 days. Moreover, stable units were more likely to remain stable in subsequent recording sessions (i.e., 89% of the neurons that were stable through four sessions remained stable on the fifth). Using both waveform and ISIH data instead of just waveforms improved performance by reducing the number of false positives. We also demonstrate that this method can be used to track neurons across days, even during adaptation to a visuomotor rotation. Identifying a stable subset of neurons should allow the study of long-term learning effects across days and has practical implications for pooling of behavioral data across days and for increasing the effectiveness of brain-machine interfaces.

Citing Articles

Historical loss weakens competitive behavior by remodeling ventral hippocampal dynamics.

Lai C, Chen K, Huang H, Huang X, Zhang J, Wang Y Cell Discov. 2025; 11(1):16.

PMID: 39994206 PMC: 11850767. DOI: 10.1038/s41421-024-00751-3.


A click-based electrocorticographic brain-computer interface enables long-term high-performance switch scan spelling.

Candrea D, Shah S, Luo S, Angrick M, Rabbani Q, Coogan C Commun Med (Lond). 2024; 4(1):207.

PMID: 39433597 PMC: 11494178. DOI: 10.1038/s43856-024-00635-3.


Tracking neurons across days with high-density probes.

van Beest E, Bimbard C, Fabre J, Dodgson S, Takacs F, Coen P Nat Methods. 2024; .

PMID: 39333269 DOI: 10.1038/s41592-024-02440-1.


Mechanically adaptive and deployable intracortical probes enable long-term neural electrophysiological recordings.

Wang S, Jiang Q, Liu H, Yu C, Li P, Pan G Proc Natl Acad Sci U S A. 2024; 121(40):e2403380121.

PMID: 39331412 PMC: 11459173. DOI: 10.1073/pnas.2403380121.


Neuroelectrophysiology-compatible electrolytic lesioning.

Bray I, Clarke S, Casey K, Nuyujukian P Elife. 2024; 12.

PMID: 39259198 PMC: 11390112. DOI: 10.7554/eLife.84385.


References
1.
Maynard E, Hatsopoulos N, Ojakangas C, Acuna B, Sanes J, Normann R . Neuronal interactions improve cortical population coding of movement direction. J Neurosci. 1999; 19(18):8083-93. PMC: 6782478. View

2.
Jackson A, Moritz C, Mavoori J, Lucas T, Fetz E . The Neurochip BCI: towards a neural prosthesis for upper limb function. IEEE Trans Neural Syst Rehabil Eng. 2006; 14(2):187-90. DOI: 10.1109/TNSRE.2006.875547. View

3.
Liu X, McCreery D, Bullara L, Agnew W . Evaluation of the stability of intracortical microelectrode arrays. IEEE Trans Neural Syst Rehabil Eng. 2006; 14(1):91-100. DOI: 10.1109/TNSRE.2006.870495. View

4.
Rousche P, Normann R . Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex. J Neurosci Methods. 1999; 82(1):1-15. DOI: 10.1016/s0165-0270(98)00031-4. View

5.
Suner S, Fellows M, Vargas-Irwin C, Nakata G, Donoghue J . Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng. 2006; 13(4):524-41. DOI: 10.1109/TNSRE.2005.857687. View