Ultrashort TE Imaging with Off-resonance Saturation Contrast (UTE-OSC)

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2009 May 19
PMID 19449436
Citations 25
Authors
Affiliations
Soon will be listed here.
Abstract

Short T(2) species such as the Achilles tendon and cortical bone cannot be imaged with conventional MR sequences. They have a much broader absorption lineshape than long T(2) species, therefore they are more sensitive to an appropriately placed off-resonance irradiation. In this work, a technique termed ultrashort TE (UTE) with off-resonance saturation contrast (UTE-OSC) is proposed to image short T(2) species. A high power saturation pulse was placed +1 to +2 kHz off the water peak to preferentially saturate signals from short T(2) species, leaving long T(2) water and fat signals largely unaffected. The subtraction of UTE images with and without an off-resonance saturation pulse effectively suppresses long T(2) water and fat signals, creating high contrast for short T(2) species. The UTE-OSC technique was validated on a phantom, and applied to bone samples and healthy volunteers on a clinical 3T scanner. High-contrast images of the Achilles tendon and cortical bone were generated with a high contrast-to-noise ratio (CNR) of the order of 12 to 20 between short T(2) and long T(2) species within a total scan time of 4 to 10 min.

Citing Articles

UTE MRI technical developments and applications in osteoporosis: a review.

Shin S, Chae H, Suprana A, Jerban S, Chang E, Shi L Front Endocrinol (Lausanne). 2025; 16:1510010.

PMID: 39980853 PMC: 11839439. DOI: 10.3389/fendo.2025.1510010.


Fast and motion-robust saturation transfer MRI with inherent B correction using rosette trajectories and compressed sensing.

Mahmud S, Singh M, van Zijl P, Heo H Magn Reson Med. 2024; 92(6):2535-2545.

PMID: 39129199 PMC: 11436307. DOI: 10.1002/mrm.30249.


Making the invisible visible-ultrashort echo time magnetic resonance imaging: Technical developments and applications.

Ma Y, Jang H, Jerban S, Chang E, Chung C, Bydder G Appl Phys Rev. 2022; 9(4):041303.

PMID: 36467869 PMC: 9677812. DOI: 10.1063/5.0086459.


Articular Cartilage Assessment Using Ultrashort Echo Time MRI: A Review.

Afsahi A, Sedaghat S, Moazamian D, Afsahi G, Athertya J, Jang H Front Endocrinol (Lausanne). 2022; 13:892961.

PMID: 35692400 PMC: 9178905. DOI: 10.3389/fendo.2022.892961.


Ultrashort Echo Time Magnetic Resonance Imaging Techniques: Met and Unmet Needs in Musculoskeletal Imaging.

Afsahi A, Ma Y, Jang H, Jerban S, Chung C, Chang E J Magn Reson Imaging. 2021; 55(6):1597-1612.

PMID: 34962335 PMC: 9106865. DOI: 10.1002/jmri.28032.