Use of Ruthenium Dyes for Subnanosecond Detector Fidelity Testing in Real Time Transient Absorption

Overview
Journal Rev Sci Instrum
Date 2009 May 2
PMID 19405646
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Transient absorption spectroscopy is a powerful tool for the study of photoreactions on time scales from femtoseconds to seconds. Typically, reactions slower than approximately 1 ns are recorded by the "classical" technique; the reaction is triggered by an excitation flash, and absorption changes accompanying the reaction are recorded in real time using a continuous monitoring light beam and a detection system with sufficiently fast response. The pico- and femtosecond region can be accessed by the more recent "pump-probe" technique, which circumvents the difficulties of real time detection on a subnanosecond time scale. This is paid for by accumulation of an excessively large number of shots to sample the reaction kinetics. Hence, it is of interest to extend the classical real time technique as far as possible to the subnanosecond range. In order to identify and minimize detection artifacts common on a subnanosecond scale, like overshoot, ringing, and signal reflections, rigorous testing is required of how the detection system responds to fast changes of the monitoring light intensity. Here, we introduce a novel method to create standard signals for detector fidelity testing on a time scale from a few picoseconds to tens of nanoseconds. The signals result from polarized measurements of absorption changes upon excitation of ruthenium complexes {[Ru(bpy)(3)](2+) and a less symmetric derivative} by a short laser flash. Two types of signals can be created depending on the polarization of the monitoring light with respect to that of the excitation flash: a fast steplike bleaching at magic angle and a monoexponentially decaying bleaching for parallel polarizations. The lifetime of the decay can be easily varied via temperature and viscosity of the solvent. The method is applied to test the performance of a newly developed real time transient absorption setup with 300 ps time resolution and high sensitivity.

Citing Articles

Dual-function artificial molecular motors performing rotation and photoluminescence.

Pfeifer L, Hoang N, Crespi S, Pshenichnikov M, Feringa B Sci Adv. 2022; 8(44):eadd0410.

PMID: 36332022 PMC: 9635830. DOI: 10.1126/sciadv.add0410.


Pushing the limits of flash photolysis to unravel the secrets of biological electron and proton transfer.

Mathis P, Sage E, Byrdin M Photochem Photobiol Sci. 2022; 21(9):1533-1544.

PMID: 35080760 DOI: 10.1007/s43630-021-00134-7.


Open hardware microsecond dispersive transient absorption spectrometer for linear optical response.

Hutchison C, Parker S, Chukhutsina V, van Thor J Photochem Photobiol Sci. 2021; 21(1):23-35.

PMID: 34748198 PMC: 8799588. DOI: 10.1007/s43630-021-00127-6.


Sub-nanosecond tryptophan radical deprotonation mediated by a protein-bound water cluster in class II DNA photolyases.

Muller P, Ignatz E, Kiontke S, Brettel K, Essen L Chem Sci. 2018; 9(5):1200-1212.

PMID: 29675165 PMC: 5885780. DOI: 10.1039/c7sc03969g.


Weak temperature dependence of P (+) H A (-) recombination in mutant Rhodobacter sphaeroides reaction centers.

Gibasiewicz K, Bialek R, Pajzderska M, Karolczak J, Burdzinski G, Jones M Photosynth Res. 2016; 128(3):243-58.

PMID: 26942583 PMC: 4877430. DOI: 10.1007/s11120-016-0239-9.