Softening and Elution of Monomers in Ethanol

Overview
Journal Dent Mater
Specialty Dentistry
Date 2009 Apr 21
PMID 19375155
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The purpose of this study was to investigate the effect of light-curing protocol on softening and elution of monomers in ethanol as measured on a model polymer. It was a further aim to correlate the measured values with previously reported data on degree of conversion and glass transition temperature for the same polymer and curing protocols.

Methods: Different light-curing protocols were used in order to investigate the influence of energy density, power density, and mode of cure on the properties of a model polymer. The modes of cure were continuous, pulse-delay, and stepped irradiation of the specimens. Wallace hardness was used to determine the softening of the polymer after storage in ethanol for 24h. Elution of monomers from the polymer was assessed after 7 days in ethanol by means of high-pressure liquid chromatography (HPLC). Data were submitted to two- and three-way analysis of variance (ANOVA), Newman-Keuls' multiple comparison test, and linear regression analysis.

Results: Energy density, power density, and mode of cure of the polymer influenced the softening and elution of monomers in ethanol. As energy density increased, softening and elution in ethanol decreased. At same energy density, the influence of power density varied with the mode of cure. When compared to the continuous mode of cure, and at same energy density, pulse-delay irradiation resulted in polymers that in general were more susceptible to softening, but eluted monomers to a lower extent. Less elution was also found with step-cured polymers. Significant, negative correlations were detected between softening and elution in ethanol, respectively, and degree of conversion and between softening and elution in ethanol, respectively, and glass transition temperature.

Significance: A complex relationship exists between curing protocol and the properties selected for investigation. The effect of different combinations of exposure periods and power densities are important to understanding how the curing protocol affects the properties of polymer-based materials.

Citing Articles

Assessment of Microhardness of Conventional and Bulk-Fill Resin Composites Using Different Light-Curing Intensity.

Jakupovic S, Pervan N, Mesic E, Gavranovic-Glamoc A, Bajsman A, Muratovic E Polymers (Basel). 2023; 15(10).

PMID: 37242825 PMC: 10224105. DOI: 10.3390/polym15102250.


Effect of Different Artificial Staining Procedures on the Color Stability and Translucency of a Nano-Hybrid Resin-Based Composite.

Paolone G, Mazzitelli C, Boggio F, Breschi L, Vichi A, Gherlone E Materials (Basel). 2023; 16(6).

PMID: 36984216 PMC: 10058860. DOI: 10.3390/ma16062336.


Effect of Chemical Challenges on the Properties of Composite Resins.

Geha O, Inagaki L, Favaro J, Gonzalez A, Guiraldo R, Lopes M Int J Dent. 2021; 2021:4895846.

PMID: 34899913 PMC: 8654529. DOI: 10.1155/2021/4895846.


The effect of rapid high-intensity light-curing on micromechanical properties of bulk-fill and conventional resin composites.

Par M, Marovic D, Attin T, Tarle Z, Taubock T Sci Rep. 2020; 10(1):10560.

PMID: 32601442 PMC: 7324583. DOI: 10.1038/s41598-020-67641-y.


Do resin-based composite CAD/CAM blocks release monomers?.

Barutcigil K, Dundar A, Batmaz S, Yildirim K, Barutcugil C Clin Oral Investig. 2020; 25(1):329-336.

PMID: 32488490 DOI: 10.1007/s00784-020-03377-3.