» Articles » PMID: 19351178

Highly Water-soluble Monoboronic Acid Probes That Show Optical Sensitivity to Glucose Based on 4-sulfo-1,8-naphthalic Anhydride

Overview
Journal J Org Chem
Specialty Chemistry
Date 2009 Apr 9
PMID 19351178
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Two highly water-soluble monoboronic acid probes that display the more desirable off-on fluorescence response were synthesized based on 4-sulfo-1,8-naphthalic anhydride and a remarkable sensitivity for glucose rather than fructose and galactose was also observed.

Citing Articles

Fluorescent naphthalimide boronates as theranostics: structural investigations, confocal fluorescence and multiphoton fluorescence lifetime imaging microscopy in living cells.

Green M, Ge H, Flower S, Pourzand C, Botchway S, Wang H RSC Chem Biol. 2023; 4(12):1082-1095.

PMID: 38033726 PMC: 10685793. DOI: 10.1039/d3cb00112a.


Carbohydrate biomarkers for future disease detection and treatment.

Cheng Y, Li M, Wang S, Peng H, Reid S, Ni N Sci China Chem. 2020; 53(1):3-20.

PMID: 32214994 PMC: 7089153. DOI: 10.1007/s11426-010-0021-3.


A fluorescent DNA based probe for Hg(II) based on thymine-Hg(II)-thymine interaction and enrichment via magnetized graphene oxide.

Li M, Hu L, Niu C, Huang D, Zeng G Mikrochim Acta. 2018; 185(3):207.

PMID: 29594626 DOI: 10.1007/s00604-018-2689-6.


Estimation of Dipole Moments and Quantum Yield of 5-chloro-2-methoxyphenyl Boronic Acid in Different Solvents Environment.

Geethanjali H, Nagaraja D, Melavanki R J Fluoresc. 2015; 25(3):745-53.

PMID: 25820873 DOI: 10.1007/s10895-015-1561-x.


A new class of fluorescent boronic acids that have extraordinarily high affinities for diols in aqueous solution at physiological pH.

Cheng Y, Ni N, Yang W, Wang B Chemistry. 2010; 16(45):13528-38.

PMID: 20938931 PMC: 3545481. DOI: 10.1002/chem.201000637.

References
1.
Pickup J, Hussain F, Evans N, Rolinski O, Birch D . Fluorescence-based glucose sensors. Biosens Bioelectron. 2005; 20(12):2555-65. DOI: 10.1016/j.bios.2004.10.002. View

2.
Gypser A, Michel D, Nirschl D, Sharpless K . Dihydroxylation of Polyenes Using Narasaka's Modification of the Upjohn Procedure. J Org Chem. 2001; 63(21):7322-7327. DOI: 10.1021/jo980850l. View

3.
Heller A . Implanted electrochemical glucose sensors for the management of diabetes. Annu Rev Biomed Eng. 2001; 1:153-75. DOI: 10.1146/annurev.bioeng.1.1.153. View

4.
Finney S, Zekveld C, Elia A, Evans T . Glucose control and mortality in critically ill patients. JAMA. 2003; 290(15):2041-7. DOI: 10.1001/jama.290.15.2041. View

5.
Cao H, McGill T, Heagy M . Substituent effects on monoboronic acid sensors for saccharides based on N-phenyl-1,8-naphthalenedicarboximides. J Org Chem. 2004; 69(9):2959-66. DOI: 10.1021/jo035760h. View