» Articles » PMID: 19286089

A Bioabsorbable Everolimus-eluting Coronary Stent System (ABSORB): 2-year Outcomes and Results from Multiple Imaging Methods

Overview
Journal Lancet
Publisher Elsevier
Specialty General Medicine
Date 2009 Mar 17
PMID 19286089
Citations 177
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Drug-eluting metallic coronary stents predispose to late stent thrombosis, prevent late lumen vessel enlargement, hinder surgical revascularisation, and impair imaging with multislice CT. We assessed the safety of the bioabsorbable everolimus-eluting stent (BVS).

Methods: 30 patients with a single de-novo coronary artery lesion were followed up for 2 years clinically and with multiple imaging methods: multislice CT, angiography, intravascular ultrasound, derived morphology parameters (virtual histology, palpography, and echogenicity), and optical coherence tomography (OCT).

Findings: Clinical data were obtained from 29 of 30 patients. At 2 years, the device was safe with no cardiac deaths, ischaemia-driven target lesion revascularisations, or stent thromboses recorded, and only one myocardial infarction (non-Q wave). 18-month multislice CT (assessed in 25 patients) showed a mean diameter stenosis of 19% (SD 9). At 2-year angiography, the in-stent late loss of 0.48 mm (SD 0.28) and the diameter stenosis of 27% (11) did not differ from the findings at 6 months. The luminal area enlargement on OCT and intravascular ultrasound between 6 months and 2 years was due to a decrease in plaque size without change in vessel size. At 2 years, 34.5% of strut locations presented no discernible features by OCT, confirming decreases in echogenicity and in radiofrequency backscattering; the remaining apparent struts were fully apposed. Additionally, vasomotion occurred at the stented site and adjacent coronary artery in response to vasoactive agents.

Interpretation: At 2 years after implantation the stent was bioabsorbed, had vasomotion restored and restenosis prevented, and was clinically safe, suggesting freedom from late thrombosis. Late luminal enlargement due to plaque reduction without vessel remodelling needs confirmation.

Citing Articles

Optimizing the Biocompatibility of PLLA Stent Materials: Strategy with Biomimetic Coating.

Du H, Li W, Li X, Qiu Z, Ding J, Zhang Y Int J Nanomedicine. 2024; 19:5157-5172.

PMID: 38855731 PMC: 11162223. DOI: 10.2147/IJN.S462691.


In Silico Evaluation of In Vivo Degradation Kinetics of Poly(Lactic Acid) Vascular Stent Devices.

He S, Wei L, Wang G, Pugno N, Chen Q, Li Z J Funct Biomater. 2024; 15(5).

PMID: 38786646 PMC: 11122488. DOI: 10.3390/jfb15050135.


Long-term efficacy, safety and biocompatibility of a novel sirolimus eluting iron bioresorbable scaffold in a porcine model.

Gao Y, Yang H, Qiu Z, Qi F, Lu Q, Zheng J Bioact Mater. 2024; 39:135-146.

PMID: 38783928 PMC: 11112549. DOI: 10.1016/j.bioactmat.2024.05.027.


Endovascular Drug Delivery.

Lungu C, Creteanu A, Mehedinti M Life (Basel). 2024; 14(4).

PMID: 38672722 PMC: 11051410. DOI: 10.3390/life14040451.


Late acquired coronary aneurysm and restenosis after bioresorbable vascular scaffold implantation: a case report.

Micari A, Dimartino A, Donato R, Vizzari G, Ando G Eur Heart J Case Rep. 2024; 8(2):ytae065.

PMID: 38332923 PMC: 10852101. DOI: 10.1093/ehjcr/ytae065.