The Effect of Including Myocardial Anisotropy in Simulated Ultrasound Images of the Heart

Overview
Date 2009 Mar 3
PMID 19251519
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

We have examined the effect of incorporating tissue anisotropy in simulated ultrasound images of the heart. In simulation studies, the cardiac muscle (myocardium) is usually modeled as a cloud of uncorrelated point scatterers. Although this approach successfully generates a realistic speckle pattern, it fails to reproduce any effects of image anisotropy seen in real ultrasound images. We hypothesize that some of this effect is caused by the varying orientation of anisotropic myocardial structures relative to the ultrasonic beam and that this can be taken into account in simulations by imposing an angle dependent correlation of the scatterer points. Ultrasound images of a porcine heart were obtained in vitro, and the dominating fiber directions were estimated from the insonification angles that gave rise to the highest backscatter intensities. A cylindrical sample of the myocardium was then modeled as a grid of point scatterers correlated in the principal directions of the muscle fibers, as determined experimentally. Ultrasound images of the model were simulated by using a fast k-space based convolution approach, and the results were compared with the in vitro recordings. The simulated images successfully reproduced the insonification dependent through-wall distribution of backscatter intensities in the myocardial sample, as well as a realistic speckle pattern.

Citing Articles

Imaging technologies for cardiac fiber and heart failure: a review.

Watson S, Dormer J, Fei B Heart Fail Rev. 2018; 23(2):273-289.

PMID: 29500602 PMC: 6121700. DOI: 10.1007/s10741-018-9684-1.


Principles of cardiovascular magnetic resonance feature tracking and echocardiographic speckle tracking for informed clinical use.

Pedrizzetti G, Claus P, Kilner P, Nagel E J Cardiovasc Magn Reson. 2016; 18(1):51.

PMID: 27561421 PMC: 5000424. DOI: 10.1186/s12968-016-0269-7.


Physiological basis in the assessment of myocardial mechanics using speckle-tracking echocardiography 2D. Part I.

Madry W, Karolczak M J Ultrason. 2016; 16(65):135-44.

PMID: 27446598 PMC: 4954859. DOI: 10.15557/JoU.2016.0015.


Simulating cardiac ultrasound image based on MR diffusion tensor imaging.

Qin X, Wang S, Shen M, Lu G, Zhang X, Wagner M Med Phys. 2015; 42(9):5144-56.

PMID: 26328966 PMC: 4537486. DOI: 10.1118/1.4927788.


DTI template-based estimation of cardiac fiber orientations from 3D ultrasound.

Qin X, Fei B Med Phys. 2015; 42(6):2915-24.

PMID: 26127045 PMC: 4441706. DOI: 10.1118/1.4921121.