» Articles » PMID: 19216256

Comparison of Avian Biochemical Test Results with Abaxis VetScan and Hitachi 911 Analyzers

Overview
Date 2009 Feb 17
PMID 19216256
Citations 12
Authors
Affiliations
Soon will be listed here.
Abstract

To compare results of clinical biochemical analysis using an Abaxis VetScan bench-top analyzer with reagents specifically marketed for avian use and a Hitachi 911 analyzer, plasma (both methods) and whole blood (VetScan method) samples from 20 clinically healthy Hispaniolan Amazon parrots (Amazona ventralis) were analyzed. Correlation between methods was very high (r = 0.9-1.0) for aspartate aminotransferase (AST), calcium, glucose, and uric acid; high (r = 0.7-0.89) for creatine kinase (CK), phosphorus, potassium, and total protein; moderate (r = 0.5-0.69) for globulin; and low (r = 0.3-0.49) for albumin and sodium. VetScan analyzer results for globulin, sodium, and uric acid had a constant negative bias (values below those from the Hitachi method). Based on difference plot analysis, results for AST, calcium, CK, and glucose are comparable. Because 16 of 20 values fell below the lower detection limit of the VetScan analyzer, bile acid data were excluded from analysis. By using a relatively small sample size (0.1 ml whole blood or plasma), the VetScan analyzer offers rapid in-house results, compact size, and ease of operation. For 4 of the most clinically relevant biochemical analytes used in avian medicine (AST, calcium, CK, glucose), it offers reliable values. For an additional 4 analytes (phosphorous, potassium, total protein, uric acid), establishing analyzer-specific reference intervals is recommended. Neither the VetScan nor the Hitachi method is recommended to assess albumin and globulin concentrations.

Citing Articles

Precision of the Abaxis VetScan VS2 for postmortem biochemical analysis of delphinid vitreous humor.

Zorotrian T, Stern A, Gao H, Costidis A, Fontaine C, Deming A Mar Mamm Sci. 2025; 39(3):893-905.

PMID: 39898359 PMC: 11784931. DOI: 10.1111/mms.13014.


Select Venous Analytes and Fibrinogen Determination Using Two Methods in Brown Pelicans.

Gessner-Knepel A, Gentry J, Schmalz S, Russell K, Jill Heatley J Animals (Basel). 2024; 14(16).

PMID: 39199898 PMC: 11350753. DOI: 10.3390/ani14162364.


Comparative impact of bacitracin and select feed additives in the feeding program of Lohmann LSL-Lite pullets at the onset of lay through to 31 weeks of age.

Kiarie E, Cheng V, Tan Z, Chen W, Xu X, Peng Y Transl Anim Sci. 2024; 8:txae013.

PMID: 38371424 PMC: 10872677. DOI: 10.1093/tas/txae013.


Response of broiler breeder pullets when fed hydrolyzed whole yeast from placement to 22 wk of age.

Maina A, Schulze H, Kiarie E Poult Sci. 2024; 103(3):103383.

PMID: 38176370 PMC: 10806125. DOI: 10.1016/j.psj.2023.103383.


Assessment of avian health status: suitability and constraints of the Zoetis VetScan VS2 blood analyser for ecological and evolutionary studies.

Xiong Y, Tobler M, Hegemann A, Hasselquist D Biol Open. 2023; 12(8).

PMID: 37485865 PMC: 10399204. DOI: 10.1242/bio.060009.