» Articles » PMID: 19163374

Automated Detection of the Carotid Artery Wall in B-mode Ultrasound Images Using Active Contours Initialized by the Hough Transform

Overview
Date 2009 Jan 24
PMID 19163374
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Automatic segmentation of the arterial lumen from ultrasound images is an important and often challenging task in clinical diagnosis. We previously used the Hough Transform (HT) to automatically extract circles from sequences of B-mode ultrasound images of transverse sections of the carotid artery. In this paper, an active-contour-based methodology is suggested, initialized by the HT circle, in an attempt to extend previous findings and to accurately detect the arterial wall boundary. The methodology is based on the generation of a gradient vector flow field, an approach attempting to overcome conventional active contours constraints. Contour estimation is then achieved by deforming the initial curve (circle) based on the gradient vector flow field. In ten normal subjects, the specificity and accuracy of the segmentation were on average higher than 0.98, whereas the sensitivity was higher than 0.82. The methodology was also applied to four subjects with atherosclerosis, in which sensitivity, specificity and accuracy were comparable to those of normal subjects. In conclusion, the HT-initialized active contours methodology provides a reliable tool to detect the carotid artery wall in ultrasound images and can be used in clinical practice.

Citing Articles

Cardiovascular Disease Risk Stratification Using Hybrid Deep Learning Paradigm: First of Its Kind on Canadian Trial Data.

Bhagawati M, Paul S, Mantella L, Johri A, Gupta S, Laird J Diagnostics (Basel). 2024; 14(17).

PMID: 39272680 PMC: 11393849. DOI: 10.3390/diagnostics14171894.


A Review on Joint Carotid Intima-Media Thickness and Plaque Area Measurement in Ultrasound for Cardiovascular/Stroke Risk Monitoring: Artificial Intelligence Framework.

Biswas M, Saba L, Omerzu T, Johri A, Khanna N, Viskovic K J Digit Imaging. 2021; 34(3):581-604.

PMID: 34080104 PMC: 8329154. DOI: 10.1007/s10278-021-00461-2.


Automated 3D geometry segmentation of the healthy and diseased carotid artery in free-hand, probe tracked ultrasound images.

de Ruijter J, van Sambeek M, van de Vosse F, Lopata R Med Phys. 2019; 47(3):1034-1047.

PMID: 31837022 PMC: 7079173. DOI: 10.1002/mp.13960.


Automatic detection of carotid arteries in computed tomography angiography: a proof of concept protocol.

Caetano Dos Santos F, Joutsen A, Paci M, Salenius J, Eskola H Int J Cardiovasc Imaging. 2016; 32(8):1299-310.

PMID: 27142430 DOI: 10.1007/s10554-016-0880-6.


Adjusting the input ultrasound image data and the atherosclerotic plaque detection in the carotid artery by the FOTOM system.

Licev L, Tomecek J, Farana R Biotechnol Biotechnol Equip. 2015; 28(3):567-575.

PMID: 26019544 PMC: 4433834. DOI: 10.1080/13102818.2014.924271.