» Articles » PMID: 19161664

Quantification of Saxitoxin and Neosaxitoxin in Human Urine Utilizing Isotope Dilution Tandem Mass Spectrometry

Overview
Journal J Anal Toxicol
Specialty Toxicology
Date 2009 Jan 24
PMID 19161664
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

Saxitoxin and neosaxitoxin are potent neurotoxins that can cause paralytic shellfish poisoning when consumed. A new assay is presented here to quantify saxitoxin (STX) and neosaxitoxin (NEO) in human urine samples. Sample preparation of 500-microL samples included the use of weak-cation-exchange solid-phase extraction in a multiplexed 96-well format. Extracts were preconcentrated and analyzed via 10-min hydrophilic interaction liquid chromatography followed by electrospray ionization. Protonated molecular ions were quantified via multiple reaction monitoring mode in a Qtrap mass spectrometer. The method uses novel 15N7-isotopically enriched STX and NEO internal standards. Method validation included the characterization of two enriched urine pools. The lowest reportable limits for STX and NEO were 4.80 and 10.1 ng/mL, respectively, using both quantification and confirmation ions. These two toxins were not detected in a reference range of humans who consumed seafood in the preceding 72 h, suggesting that few false positives would occur when trying to identify people exposed to STX or NEO.

Citing Articles

Review of the occurrence, treatment technologies, and detection methods for saxitoxins in freshwaters.

Gawankar S, Masten S, Lahr R J Water Health. 2024; 22(8):1472-1490.

PMID: 39212282 DOI: 10.2166/wh.2024.106.


Quantitation Overcoming Matrix Effects of Lipophilic Toxins in by Liquid Chromatography-Full Scan High Resolution Mass Spectrometry Analysis (LC-HR-MS).

Costa C, Afonso I, Lage S, Costa P, Canario A, Da Silva J Mar Drugs. 2022; 20(2).

PMID: 35200672 PMC: 8880440. DOI: 10.3390/md20020143.


Quantification of saxitoxin in human blood by ELISA.

Wharton R, Feyereisen M, Gonzalez A, Abbott N, Hamelin E, Johnson R Toxicon. 2017; 133:110-115.

PMID: 28495477 PMC: 6234504. DOI: 10.1016/j.toxicon.2017.05.009.


Development and validation of a high-throughput online solid phase extraction - Liquid chromatography - Tandem mass spectrometry method for the detection of tetrodotoxin in human urine.

Coleman R, Lemire S, Bragg W, Garrett A, Ojeda-Torres G, Hamelin E Toxicon. 2016; 119:64-71.

PMID: 27212629 PMC: 6943750. DOI: 10.1016/j.toxicon.2016.05.009.


Marine harmful algal blooms, human health and wellbeing: challenges and opportunities in the 21st century.

Berdalet E, Fleming L, Gowen R, Davidson K, Hess P, Backer L J Mar Biol Assoc U K. 2015; 2015.

PMID: 26692586 PMC: 4676275. DOI: 10.1017/S0025315415001733.