Development and Preliminary Validation of Heart Rate and Breathing Rate Detection Using a Passive, Ballistocardiography-based Sleep Monitoring System

Overview
Date 2009 Jan 9
PMID 19129030
Citations 37
Authors
Affiliations
Soon will be listed here.
Abstract

Techniques such as ballistocardiography (BCG) that can provide noninvasive long-term physiological monitoring have gained interest due to a growing recognition of adverse effects from poor sleep and sleep disorders. The noninvasive analysis of physiological signals (NAPS) system is a BCG-based monitoring system developed to measure heart rate, breathing rate, and musculoskeletal movement that shows promise as a general sleep analysis tool. Overnight sleep studies were conducted on 40 healthy subjects during a clinical trial at the University of Virginia. The NAPS system's measures of heart rate and breathing rate were compared to ECG, pulse oximetry, and respiratory inductance plethysmography (RIP). The subjects were split into a training dataset and a validation dataset, maintaining similar demographics in each set. The NAPS system accurately detected heart rate, averaged over the prescribed 30-s epochs, to within less than 2.72 beats per minute of ECG, and accurately detected breathing rate, averaged over the same epochs, to within 2.10 breaths per minute of RIP bands used in polysomnography.

Citing Articles

Transforming Sleep Monitoring: Review of Wearable and Remote Devices Advancing Home Polysomnography and Their Role in Predicting Neurological Disorders.

Vitazkova D, Kosnacova H, Turonova D, Foltan E, Jagelka M, Berki M Biosensors (Basel). 2025; 15(2).

PMID: 39997019 PMC: 11853583. DOI: 10.3390/bios15020117.


Advances in Respiratory Monitoring: A Comprehensive Review of Wearable and Remote Technologies.

Vitazkova D, Foltan E, Kosnacova H, Micjan M, Donoval M, Kuzma A Biosensors (Basel). 2024; 14(2).

PMID: 38392009 PMC: 10886711. DOI: 10.3390/bios14020090.


Validating Force Sensitive Resistor Strip Sensors for Cardiorespiratory Measurement during Sleep: A Preliminary Study.

Haghi M, Asadov A, Boiko A, Ortega J, Madrid N, Seepold R Sensors (Basel). 2023; 23(8).

PMID: 37112315 PMC: 10141142. DOI: 10.3390/s23083973.


Effects of Ballistocardiogram Peak Detection Jitters on the Quality of Heart Rate Variability Features: A Simulation-Based Case Study in the Context of Sleep Staging.

Suliman A, Mowla M, Alivar A, Carlson C, Prakash P, Natarajan B Sensors (Basel). 2023; 23(5).

PMID: 36904896 PMC: 10007206. DOI: 10.3390/s23052693.


Air-mattress system for ballistocardiogram-based heart rate and breathing rate estimation.

Lin C, Sun Z, Chen Y Heliyon. 2023; 9(1):e12717.

PMID: 36685401 PMC: 9849971. DOI: 10.1016/j.heliyon.2022.e12717.