» Articles » PMID: 19090631

Effect of Carotid Angioplasty and Stenting on Duplex Velocity Measurements in a Porcine Model

Overview
Journal J Endovasc Ther
Publisher Sage Publications
Date 2008 Dec 19
PMID 19090631
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To evaluate if there are any differences in duplex ultrasound velocity measurements between native and stented carotid arteries using duplex ultrasound in an animal model.

Methods: The common carotid artery of 5 pigs was exposed bilaterally (10 arteries). Diameters and velocities were measured by ultrasound in the proximal, mid, and distal native artery at the intended site of stent implantation. Measurements were repeated after bilateral stent placement (Wallstent versus Precise) under angiographic control. Outcomes of native versus stented arteries and Wallstent versus Precise were statistically compared.

Results: Angiographic measurements matched well with duplex-measured diameters. The mean proximal stent diameter (3.5+/-0.5 mm) was significantly smaller than the native proximal artery diameter (4.2+/-0.4 mm, p = 0.004), mostly due to narrowing of the Wallstent diameter to 3.2+/-0.5 mm (p = 0.009). Proximal, mid, and distal segments of the Wallstents were narrower than those of the Precise stent, and associated peak systolic velocities (PSV) were higher at the 3 locations versus the Precise stent, although the differences were not statistically significant. Wallstent PSVs were higher than in the native artery at the proximal, mid, and distal segments, respectively; again, the differences were not statistically significant.

Conclusion: Stent placement caused anatomical and hemodynamic alterations. Narrowings and associated increased velocities were noted. Such alterations, however, were stent-type dependent and did not justify a general approach to new velocity criteria indiscriminately applied to all stents.

Citing Articles

Letter to the editor on: "Effect of different targets of goal-directed fluid therapy on intraoperative hypotension and fluid infusion in robot-assisted laparoscopic gynecological surgery: a randomized non-inferiority trial".

Satici M J Robot Surg. 2024; 18(1):258.

PMID: 38900397 DOI: 10.1007/s11701-024-02025-2.


Assessment of Plaque Characteristics by Contrast-Enhanced Ultrasound and Stent Restenosis following Carotid Artery Stenting: A Retrospective Study.

Gimzauskaite A, Inciura D, Diringyte G, Lukosevicius S, Kaupas R, Pranculis A Medicina (Kaunas). 2024; 60(5).

PMID: 38793019 PMC: 11123181. DOI: 10.3390/medicina60050836.


Effects of helical centerline stent vs. straight stent placement on blood flow velocity.

Kohata Y, Ohta M, Jin K, Anzai H Front Med Technol. 2023; 5:1196125.

PMID: 37333882 PMC: 10272720. DOI: 10.3389/fmedt.2023.1196125.


Assessment of Large Animal Vascular Dimensions for Intra-Aortic Device Research and Development: A Systematic Review.

Georges G, Couture T, Voisine P Innovations (Phila). 2023; 18(2):144-151.

PMID: 37029653 PMC: 10159216. DOI: 10.1177/15569845231164134.


Optimal cut-off criteria for duplex ultrasound compared with computed tomography angiography for the diagnosis of restenosis in stented carotid arteries in the international carotid stenting study.

Bosch F, Hendrikse J, Davagnanam I, Bonati L, van der Lugt A, van der Worp H Eur Stroke J. 2019; 2(1):37-45.

PMID: 31008301 PMC: 6453175. DOI: 10.1177/2396987316678361.