» Articles » PMID: 19038282

Model Systems for the Discovery and Development of Antiarrhythmic Drugs

Overview
Date 2008 Nov 29
PMID 19038282
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Cardiovascular diseases are the leading cause of mortality worldwide and about 25% of cardiovascular deaths are due to disturbances in cardiac rhythm or "arrhythmias". Arrhythmias were traditionally treated with antiarrhythmic drugs, but increasing awareness of the risks of presently available antiarrhythmic agents has greatly limited their usefulness. Most common treatment algorithms still involve small molecule drugs, and antiarrhythmic agents with improved efficacy and safety are sorely needed. This paper reviews the model systems that are available for discovery and development of new antiarrhythmic drugs. We begin with a presentation of screening methods used to identify specific channel-interacting agents, with a particular emphasis on high-throughput screens. Traditional manual electrophysiological methods, automated electrophysiology, fluorescent dye methods, flux assays and radioligand binding assays are reviewed. We then discuss a variety of relevant arrhythmia models. Two models are widely used in testing for arrhythmogenic actions related to excess action potential prolongation, an important potential adverse effect of chemical entities affecting cardiac rhythm: the methoxamine-sensitized rabbit and the dog with chronic atrioventricular block. We then go on to review models used to assess potential antiarrhythmic actions. For ventricular arrhythmias, chemical induction methods, cardiac or neural electrical stimulation, ischaemic heart models and models of cardiac channelopathies can be used to identify effective antiarrhythmic agents. For atrial arrhythmias, potentially useful models include vagally-maintained atrial fibrillation, acute asphyxia with atrial burst-pacing, sterile pericarditis, Y-shaped atria surgical incisions, chronic atrial dilation models, atrial electrical remodelling due to sustained atrial tachycardia, heart failure-related atrial remodelling, and acute atrial ischaemia. It is hoped that the new technologies now available and the recently-developed models for arrhythmia-response assessment will permit the introduction of newer and more effective antiarrhythmic therapies in the near future.

Citing Articles

Experimental study of local anesthetic and antiarrhythmic activities of fluorinated ethynylpiperidine derivatives.

Satbayeva E, Zhumakova S, Khaiitova M, Kemelbekov U, Tursunkhodzhaeva F, Azamatov A Braz J Med Biol Res. 2024; 57:e13429.

PMID: 39082579 PMC: 11290815. DOI: 10.1590/1414-431X2024e13429.


Rabbit-specific computational modelling of ventricular cell electrophysiology: Using populations of models to explore variability in the response to ischemia.

Gemmell P, Burrage K, Rodriguez B, Quinn T Prog Biophys Mol Biol. 2016; 121(2):169-84.

PMID: 27320382 PMC: 5405055. DOI: 10.1016/j.pbiomolbio.2016.06.003.


Rabbit models of cardiac mechano-electric and mechano-mechanical coupling.

Quinn T, Kohl P Prog Biophys Mol Biol. 2016; 121(2):110-22.

PMID: 27208698 PMC: 5067302. DOI: 10.1016/j.pbiomolbio.2016.05.003.


Population of computational rabbit-specific ventricular action potential models for investigating sources of variability in cellular repolarisation.

Gemmell P, Burrage K, Rodriguez B, Quinn T PLoS One. 2014; 9(2):e90112.

PMID: 24587229 PMC: 3938586. DOI: 10.1371/journal.pone.0090112.


Identification and characterization of a compound that protects cardiac tissue from human Ether-à-go-go-related gene (hERG)-related drug-induced arrhythmias.

Potet F, Lorinc A, Chaigne S, Hopkins C, Venkataraman R, Stepanovic S J Biol Chem. 2012; 287(47):39613-25.

PMID: 23033485 PMC: 3501040. DOI: 10.1074/jbc.M112.380162.