Radiographic Film Dosimetry for IMRT Fields in the Nearsurface Buildup Region

Overview
Date 2008 Nov 21
PMID 19020480
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Radiographic film dosimetry provides fast, convenient 2-D dose distributions, but is challenged by the dependence of film response on scatter conditions (i.e., energy dependence). Verification of delivered dose in the surface buildup region is important for intensity modulated radiation therapy (IMRT) when volumes of interest encroach on these regions (e.g., head/neck, breast). The current work demonstrates that film dosimetry can accurately predict the dose in the buildup region for IMRT, since 1) film dosimetry can be performed with sufficient accuracy for small fields and 2) IMRT is delivered by a series of "small" segments (step and shoot IMRT). This work evaluates the accuracy of X-OMAT V (XV) and Extended Dose Range (EDR) film for measurements from 2 mm to 15 mm depths for small fields and clinical IMRT beams. Film measurements have been compared to single point measurements made with a stereotactic diode and parallel plate ionization chamber (P11) and thermoluminescent dosimeters (TLD) at various depths for square (diode, P11) and IMRT (diode, TLD) fields. Film calibration was performed using an 8-field step exposure on a single film at 5 cm depth, which has been corrected to represent either small field or large field depth dependent film calibration techniques. Up to 10% correction for film response variation as a function of depth was required for measurements in the buildup region. A depth-dependent calibration can sufficiently improve the accuracy for IMRT calculation verification (i.e., < or = 5% uncertainty). A small field film calibration technique was most appropriate for IMRT field measurements. Improved buildup region dose measurements for clinical IMRT fields promotes improved dose estimation performance for (inverse) treatment planning and allows more quantitative treatment delivery validation.

Citing Articles

Polyphenolic extracts from the xerophyte Rhamnus lycioides as a radiation biodosimeter.

Guesmi S, Raouafi A, Amri I, Hamzaoui A, Boulila A, Hosni F Environ Sci Pollut Res Int. 2018; 27(6):5661-5669.

PMID: 30484056 DOI: 10.1007/s11356-018-3709-0.


Transit dosimetry in dynamic IMRT with an a-Si EPID.

Sabet M, Rowshanfarzad P, Menk F, Greer P Med Biol Eng Comput. 2014; 52(7):579-88.

PMID: 24878699 DOI: 10.1007/s11517-014-1161-y.


Anatomy-corresponding method of IMRT verification.

Winiecki J, Zurawski Z, Drzewiecka B, Slosarek K Rep Pract Oncol Radiother. 2013; 16(1):1-9.

PMID: 24376949 PMC: 3863168. DOI: 10.1016/j.rpor.2010.11.001.


Superficial dosimetry imaging based on Čerenkov emission for external beam radiotherapy with megavoltage x-ray beam.

Zhang R, Glaser A, Gladstone D, Fox C, Pogue B Med Phys. 2013; 40(10):101914.

PMID: 24089916 PMC: 3790817. DOI: 10.1118/1.4821543.


Superficial dosimetry imaging of Čerenkov emission in electron beam radiotherapy of phantoms.

Zhang R, Fox C, Glaser A, Gladstone D, Pogue B Phys Med Biol. 2013; 58(16):5477-93.

PMID: 23880473 PMC: 4143764. DOI: 10.1088/0031-9155/58/16/5477.

References
1.
Sankar A, Ayyangar K, Nehru R, Gopalakrishna Kurup P, Murali V, Enke C . Comparison of Kodak EDR2 and Gafchromic EBT film for intensity-modulated radiation therapy dose distribution verification. Med Dosim. 2006; 31(4):273-82. DOI: 10.1016/j.meddos.2006.06.001. View

2.
Kirov A, Caravelli G, Palm A, Chui C, LoSasso T . Pencil beam approach for correcting the energy dependence artifact in film dosimetry for IMRT verification. Med Phys. 2006; 33(10):3690-9. DOI: 10.1118/1.2229425. View

3.
Thomas S, Hoole A . The effect of optimization on surface dose in intensity modulated radiotherapy (IMRT). Phys Med Biol. 2004; 49(21):4919-28. DOI: 10.1088/0031-9155/49/21/005. View

4.
Rawlinson J, Arlen D, Newcombe D . Design of parallel plate ion chambers for buildup measurements in megavoltage photon beams. Med Phys. 1992; 19(3):641-8. DOI: 10.1118/1.596896. View

5.
Devic S, Seuntjens J, Sham E, Podgorsak E, Schmidtlein C, Kirov A . Precise radiochromic film dosimetry using a flat-bed document scanner. Med Phys. 2005; 32(7):2245-53. DOI: 10.1118/1.1929253. View