» Articles » PMID: 19014457

Statistical Methods to Correct for Verification Bias in Diagnostic Studies Are Inadequate when There Are Few False Negatives: a Simulation Study

Overview
Publisher Biomed Central
Date 2008 Nov 19
PMID 19014457
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Background: A common feature of diagnostic research is that results for a diagnostic gold standard are available primarily for patients who are positive for the test under investigation. Data from such studies are subject to what has been termed "verification bias". We evaluated statistical methods for verification bias correction when there are few false negatives.

Methods: A simulation study was conducted of a screening study subject to verification bias. We compared estimates of the area-under-the-curve (AUC) corrected for verification bias varying both the rate and mechanism of verification.

Results: In a single simulated data set, varying false negatives from 0 to 4 led to verification bias corrected AUCs ranging from 0.550 to 0.852. Excess variation associated with low numbers of false negatives was confirmed in simulation studies and by analyses of published studies that incorporated verification bias correction. The 2.5th - 97.5th centile range constituted as much as 60% of the possible range of AUCs for some simulations.

Conclusion: Screening programs are designed such that there are few false negatives. Standard statistical methods for verification bias correction are inadequate in this circumstance.

Citing Articles

Validating pertussis data measures using electronic medical record data in Ontario, Canada 1986-2016.

McBurney S, Kwong J, Brown K, Rudzicz F, Chen B, Candido E Vaccine X. 2024; 15:100408.

PMID: 38161988 PMC: 10755117. DOI: 10.1016/j.jvacx.2023.100408.


Diagnostic Accuracy of the Telephone Interview for Cognitive Status for the Detection of Dementia in Primary Care.

Abdulrahman H, Jansen E, Hoevenaar-Blom M, van Dalen J, van Wanrooij L, van Bussel E Ann Fam Med. 2022; 20(2):130-136.

PMID: 35346928 PMC: 8959747. DOI: 10.1370/afm.2768.


Adjusting for verification bias in diagnostic accuracy measures when comparing multiple screening tests - an application to the IP1-PROSTAGRAM study.

Day E, Eldred-Evans D, Prevost A, Ahmed H, Fiorentino F BMC Med Res Methodol. 2022; 22(1):70.

PMID: 35300611 PMC: 8932251. DOI: 10.1186/s12874-021-01481-w.


Comparative accuracy of cervical cancer screening strategies in healthy asymptomatic women: a systematic review and network meta-analysis.

Terasawa T, Hosono S, Sasaki S, Hoshi K, Hamashima Y, Katayama T Sci Rep. 2022; 12(1):94.

PMID: 34997127 PMC: 8741996. DOI: 10.1038/s41598-021-04201-y.


Sojourn-time-corrected receiver operating characteristic curve (ROC) for prostate specific antigen (PSA) test in population-based prostate cancer screening.

Jen H, Chang W, Hsu C, Yen A, Auvinen A, Chen T Sci Rep. 2020; 10(1):20665.

PMID: 33244038 PMC: 7691355. DOI: 10.1038/s41598-020-77668-w.


References
1.
Begg C, Greenes R . Assessment of diagnostic tests when disease verification is subject to selection bias. Biometrics. 1983; 39(1):207-15. View

2.
Schneider A, Hoyer H, Lotz B, Leistritza S, Kuhne-Heid R, Nindl I . Screening for high-grade cervical intra-epithelial neoplasia and cancer by testing for high-risk HPV, routine cytology or colposcopy. Int J Cancer. 2000; 89(6):529-34. View

3.
Thompson I, Ankerst D, Chi C, Goodman P, Tangen C, Lucia M . Assessing prostate cancer risk: results from the Prostate Cancer Prevention Trial. J Natl Cancer Inst. 2006; 98(8):529-34. DOI: 10.1093/jnci/djj131. View

4.
Roger V, Pellikka P, Bell M, Chow C, Bailey K, Seward J . Sex and test verification bias. Impact on the diagnostic value of exercise echocardiography. Circulation. 1997; 95(2):405-10. DOI: 10.1161/01.cir.95.2.405. View

5.
Dannecker C, Siebert U, Thaler C, Kiermeir D, Hepp H, Hillemanns P . Primary cervical cancer screening by self-sampling of human papillomavirus DNA in internal medicine outpatient clinics. Ann Oncol. 2004; 15(6):863-9. DOI: 10.1093/annonc/mdh240. View