Validation and Comparison of Two Multiplex Technologies, Luminex and Mesoscale Discovery, for Human Cytokine Profiling

Overview
Publisher Elsevier
Date 2008 Nov 6
PMID 18983846
Citations 119
Authors
Affiliations
Soon will be listed here.
Abstract

Biomarker research has rapidly expanded over recent years aided by the progressive development of research tools, in particular the different multiplex technologies allowing simultaneous measurement of multiple analytes. It is foreseeable that such technology will have an integral role in clinical studies for establishing biomarker profiles of disease status, but validation of the tools is essential to confirm the reliability of their application. More comparable studies between multiplex platforms are required to enable users to determine which of these are best for a particular clinical study, as different platforms will have varying levels of performance for the validation parameters. Comparison of two multiplex platforms, the Luminex and the Mesoscale Discovery, has been performed to determine their performance for the validation parameters of sensitivity, precision and accuracy for the cytokines IL-2, IL-4, IL-8, IL-10, IL-12, IFNgamma and TNFalpha. When measuring high concentrations both platforms show good accuracy (within +/-25% recovery) with all cytokines except IL-12 for the MSD. At low concentrations, +/-25% recovery was seen with all cytokines except IL-2 and IL-8 for the Luminex and IL-2 and IL-12 for the MSD. Although quantitative differences are found, relative differences are comparable, and consequently both platforms have been shown to be suitable for analyzing trends in multiple cytokine profiles, with the Luminex having better precision and the Mesoscale Discovery having greater sensitivity.

Citing Articles

Comparison of highly sensitive, multiplex immunoassay platforms for streamlined clinical cytokine quantification.

McKinski K, Tang H, Wang K, Birchler M, Wright M Bioanalysis. 2024; 17(1):17-29.

PMID: 39703153 PMC: 11749433. DOI: 10.1080/17576180.2024.2442190.


Sources of variability in Luminex bead-based cytokine assays: Evidence from twelve years of multi-site proficiency testing.

Rountree W, Lynch H, Denny T, Sempowski G, Macintyre A J Immunol Methods. 2024; 531:113699.

PMID: 38823575 PMC: 11246216. DOI: 10.1016/j.jim.2024.113699.


Rationale and Design of a Phase 2, Double-blind, Placebo-Controlled, Randomized Trial Evaluating AMP Kinase-Activation by Metformin in Focal Segmental Glomerulosclerosis.

Barsotti G, Luciano R, Kumar A, Meliambro K, Kakade V, Tokita J Kidney Int Rep. 2024; 9(5):1354-1368.

PMID: 38707807 PMC: 11068976. DOI: 10.1016/j.ekir.2024.02.006.


Quantitative analysis of pertussis, tetanus, and diphtheria antibodies in sera and breast milk from Tdap vaccinated women using a qualified multiplex assay.

Portillo S, Oshinsky J, Williams M, Yoder S, Liang Y, Campbell J mSphere. 2024; 9(4):e0052723.

PMID: 38497618 PMC: 11036809. DOI: 10.1128/msphere.00527-23.


Immunocapture LC-MS methods for pharmacokinetics of large molecule drugs.

Werth E, Roos D, Philip E Bioanalysis. 2024; 16(7):165-177.

PMID: 38348660 PMC: 11845110. DOI: 10.4155/bio-2023-0261.