» Articles » PMID: 18970145

Synthesis and Application of a Functionalized Resin for Flow Injection/F AAS Copper Determination in Waters

Overview
Journal Talanta
Publisher Elsevier
Specialty Chemistry
Date 2008 Oct 31
PMID 18970145
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

This paper reports the development of a new strategy for low-level determination of copper in water samples by using a flow-injection system coupled to solid-phase extraction (SPE) using flame atomic absorption spectrometry (F AAS) as detector. In order to preconcentrate copper from samples, a minicolumn packed with a styrene-divinylbenzene resin functionalized with (S)-2-[hydroxy-bis-(4-vinyl-phenyl)-methyl]-pyrrolidine-1-carboxylic acid ethyl ester was used and the synthesis procedure is described. System operation is based on the on-line retention of Cu(II) ions at pH 9.0+/-0.2 in a such minicolumn with posterior analyte elution with 2moll(-1) HCl directly to the F AAS nebulizer. The influence of several chemical (sample pH, buffer concentration, HCl eluent concentration and effect of the ionic strength) and flow (sample and eluent flow rates and preconcentration time) variables that could affect the performance of this system were investigated as well as the possible interferents. At optimized conditions, for 2min of preconcentration time (13.2ml of sample volume), the system achieved a detection limit of 1.1mugl(-1), a R.S.D. 1% at 20muggl(-1) and an analytical throughput of 25h(-1), whereas for 4min of preconcentration time (26.4ml of sample volume), a detection limit of 0.93mugl(-1), a R.S.D. 5.3% at 5mugl(-1) and a sampling frequency of 13h(-1) were reported.

Citing Articles

Construction of an optical sensor for copper determination in environmental, food, and biological samples based on the covalently immobilized 2-(2-benzothiazolylazo)-3-hydroxyphenol in agarose.

Aish M, Alshehri R, Amin A RSC Adv. 2023; 13(35):24777-24788.

PMID: 37601595 PMC: 10437093. DOI: 10.1039/d3ra04249a.


Amino acid-functionalized carbon quantum dots for selective detection of Al ions and fluorescence imaging in living cells.

Yan C, Guo L, Shao X, Shu Q, Guan P, Wang J Anal Bioanal Chem. 2021; 413(15):3965-3974.

PMID: 33909083 DOI: 10.1007/s00216-021-03348-x.


Schiff Base Derived from 4,4'-methylenedianiline and p-anisaldehyde: Colorimetric Sensor for Cu, Paper Strip Sensor for Al and Fluorescent Sensor for Pb.

Das D, Deka S, Guha A J Fluoresc. 2019; 29(6):1467-1474.

PMID: 31786706 DOI: 10.1007/s10895-019-02443-8.


Metal Cation Detection in Drinking Water.

Dalmieda J, Kruse P Sensors (Basel). 2019; 19(23).

PMID: 31771173 PMC: 6928949. DOI: 10.3390/s19235134.


Fabrication of a Cu(II)-Selective Electrode in the Polyvinyl Chloride Matrix Utilizing Mechanochemically Synthesized Rhodamine 6g as an Ionophore.

Paul A, Nair R, Chatterjee P, Srivastava D ACS Omega. 2019; 3(11):16230-16237.

PMID: 31458258 PMC: 6643935. DOI: 10.1021/acsomega.8b02870.