» Articles » PMID: 18969509

Validation of Bismuth Film Electrode for Determination of Cobalt and Cadmium in Soil Extracts Using ICP-MS

Overview
Journal Talanta
Publisher Elsevier
Specialty Chemistry
Date 2008 Oct 31
PMID 18969509
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

A study is presented on the use of the bismuth film electrode (BiFE) operated in the anodic stripping and the cathodic adsorptive stripping voltammetry (ASV, CAdSV) modes, for the determination of two trace heavy metals (Cd and Co, respectively), in soil extract samples. Two types of BiFE were examined in this study: the in situ prepared BiFE, which was employed in ASV determination of Cd, and the ex situ prepared BiFE, which was used in CAdSV of Co with dimethylglyoxime (DMG) as complexing agent. A series of unpretreated soil extracts with varying Cd and Co concentrations were analyzed, and the results obtained compared to those determined using inductively coupled plasma-mass spectrometry (ICP-MS). The results revealed the suitability of stripping analysis at the BiFE for determination of mugl(-1) levels of heavy metals in soil extracts. The promising results obtained here, coupled with the non-toxic nature of bismuth (in comparison to commonly used mercury electrodes employed in stripping analysis), offer great promise in centralized and decentralized analysis of trace heavy metals in complex environmental matrices.

Citing Articles

New Prospects in the Electroanalysis of Heavy Metal Ions (Cd, Pb, Zn, Cu): Development and Application of Novel Electrode Surfaces.

Keramari V, Karastogianni S, Girousi S Methods Protoc. 2023; 6(4).

PMID: 37489427 PMC: 10366748. DOI: 10.3390/mps6040060.


An Electrochemical Sensor for the Determination of Trace Concentrations of Cadmium, Based on Spherical Glassy Carbon and Nanotubes.

Grabarczyk M, Wardak C, Piech R, Wawruch A Materials (Basel). 2023; 16(8).

PMID: 37110088 PMC: 10146725. DOI: 10.3390/ma16083252.


A Novel Imidazole Bound Schiff Base as Highly Selective "Turn-on" Fluorescence Sensor for Zn and Colorimetric Kit for Co.

Gopalakrishnan A, Angamaly S, Pradeep S, Madhusoodhanan D, Manoharan D, Mohanan P J Fluoresc. 2021; 32(1):189-202.

PMID: 34687395 DOI: 10.1007/s10895-021-02839-5.


Bipyridine-linked three-dimensional covalent organic frameworks for fluorescence sensing of cobalt(II) at nanomole level.

Wang L, Chen Y, Zhang Z, Chen Y, Deng Q, Wang S Mikrochim Acta. 2021; 188(5):167.

PMID: 33877439 DOI: 10.1007/s00604-021-04813-1.


Visual Simultaneous Detection and Real-Time Monitoring of Cadmium Ions Based on Conjugated Polydiacetylenes.

Pham T, Lee S, Kim D, Jung O, Lee M, Lee S ACS Omega. 2020; 5(48):31254-31261.

PMID: 33324835 PMC: 7726929. DOI: 10.1021/acsomega.0c04636.